Chapter 6 Maintenance and inspections (continued)

LENS

1

RET-SW

ON/OFF of the return video

 

 

RETURN ON: GND

 

 

RETURN OFF: OPEN

 

 

 

 

 

 

 

 

 

 

 

2

REC-START/STOP

Control for recording start/stop

 

 

 

 

 

 

 

 

 

 

+5 V

 

 

 

 

 

 

 

 

 

 

0 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

START STOP START

 

 

 

 

 

 

 

 

 

 

 

3

GND

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

IRIS-AUTO

ON/OFF of the forced iris servo

 

 

SERVO ON:

+5 V ±0.5 V

 

 

SERVO OFF: OPEN

 

 

 

 

 

 

 

 

 

 

 

5

IRIS-CONT

Control output for the lens iris

 

 

F2.8: –6.2 V, F16: +3.4 V, CLOSE: +2.5 V

 

 

 

 

 

 

 

 

 

 

 

6

UNREG-12V

+12V power supply for the lens (Max. 1.5 A)

 

 

 

 

 

 

 

 

 

 

 

7

IRIS-POSI

Iris position signals

 

 

3.4 V (F16) to +6.2 V (F2.8)

 

 

 

 

 

 

 

 

 

 

 

8

IRIS-G-MAX

IRIS REMOTE/LOCAL (AUTO) signals

 

 

REMOTE:

 

+5 V ±0.5 V

 

 

LOCAL (AUTO): GND

 

 

 

 

 

 

 

 

 

 

 

9

EXT-POSI

ON/OFF of the built-in extender

 

 

EXTENDER ON: GND

 

 

EXTENDER OFF: OPEN

 

 

 

 

 

 

 

 

 

 

 

10

ZOOM-POSI

Zoom position signals

 

 

 

 

 

 

 

 

 

 

 

11

FOCUS-POSI

Focus position signals

 

 

 

 

 

 

 

 

 

 

 

12

SPARE

Standby (not used)

 

 

 

 

 

 

 

 

 

 

 

Matsushita part number K1AY112JA001

Maker part number

HR10A-10R-12SC(71)

 

(Hirose Denki)

91

8 10 2

7 12 11 3

6

4

 

5

GPS

1

GPS TXA

Transmission data from the GPS unit to the camera

 

 

 

2

GPS RXA

Transmission data from the camera to the GPS unit

 

 

 

3

GPS VBAT

Backup power supply connector for the GPS unit

 

 

(DC+3.3 V)

 

 

 

4

REC START SW

Control signals of REC start/stop

 

 

 

5

GPS VCC

Power supply connector for the GPS unit (DC+3.3 V)

 

 

 

6

GPS GND

GND

 

 

 

Matsushita part number K1AY106J0001

Maker part number

HR10A-7R-6SC(73)

 

(Hirose Denki)

6 1

52

4 3

96