Chapter 7 Menu description tables (continued)
Item | Variable | Remarks | |
range | |||
|
| ||
|
|
| |
HUMID OPE | ON | For selecting whether or not to continue | |
| OFF | operation when HUMID alarm state has | |
|
| occurred. | |
|
| ON: Operation continues until tape slack is | |
|
| detected even when the HUMID alarm | |
|
| state has occurred during operation. | |
|
| OFF: Operation is stopped as soon as the | |
|
| HUMID alarm state occurs. | |
|
| If the HUMID alarm state occurs during | |
|
| recording, the recording operation will | |
|
| continue unless tape slack is detected | |
|
| regardless of whether ON or OFF has been | |
C U F |
| selected as this item’s setting. | |
|
|
| |
REC START | ALL | For selecting how recording start is to be | |
C U F | NORMAL | accepted. | |
|
| ||
|
|
| |
PAUSE TIMER | 10min | For selecting the time during which REC/ | |
| 20min | PAUSE is to continue. | |
| 30min |
| |
C U F | 60min |
| |
|
| ||
|
|
| |
RC CHECK SW | R.REVIEW | For setting the operations of the unit by | |
| RETAKE | using the REC check button on the remote | |
|
| control unit. | |
|
| R.REVIEW: The | |
|
| performed. | |
|
| RETAKE: The retake operation is | |
|
| performed, after which playback | |
C U F |
| is initiated automatically. | |
|
| ||
|
|
| |
COMPRESSION | NORMAL | For selecting the DVCPRO compression | |
MODE | DARK | mode. | |
|
| O This is enabled when the recording format | |
|
| is set to 720P. | |
|
| NORMAL: | |
|
| Normal shooting shall be executed in this | |
|
| mode. | |
|
| DARK: | |
|
| Distortion of compressed video images | |
|
| that may occur at dark parts on the video | |
|
| images can be suppressed in this mode. | |
|
| Distortion of compressed video images on | |
C U F |
| other parts may increase. | |
|
|
|
The underlining in the variable range column indicates the setting in the preset mode.
Item | Variable |
|
| Remarks |
|
| |
range |
|
|
|
| |||
|
|
|
|
|
|
| |
|
|
| |||||
BATTERY SELECT | PROPAC14 | For selecting the type of battery to be used. | |||||
| TRIMPAC14 | The remaining | charge is | detected | in | ||
| HYTRON50 | accordance with the battery which has been | |||||
| HYTRON120 | ||||||
| selected. |
|
|
|
|
| |
| DIONIC90 |
|
|
|
|
| |
| The variable range is changed by the item | ||||||
| DIONIC160 | ||||||
| settings selected on the | ||||||
| |||||||
| SETTING1” | and | BATTERY | ||||
| ENDURA7 | ||||||
| SETTING2” menus. |
|
|
| |||
| ENDURA10 |
|
|
| |||
| ENDURA D | The initial value for TYPE A is set to | |||||
| PAG L95 | DIONIC100 while the same for TYPE B is | |||||
| set to HYTRON100. |
|
|
| |||
| NICD14 |
|
|
| |||
|
|
|
|
|
|
| |
| TYPE A |
|
|
|
|
|
|
C U F | TYPE B |
|
|
|
|
|
|
|
|
| |||||
EXT DC IN | AC_ADPT | For selecting the external power supply to | |||||
SELECT | PROPAC14 | connect to the DC IN socket. |
|
| |||
| TRIMPAC14 | The variable range is changed by the item | |||||
| HYTRON50 | ||||||
| settings selected on the | ||||||
| HYTRON120 | ||||||
| SETTING1” | and | BATTERY | ||||
| DIONIC90 | ||||||
| SETTING2” menus. |
|
|
| |||
| DIONIC160 |
|
|
| |||
| Analog voltage | is | displayed on | the | |||
| |||||||
| viewfinder screen. |
|
|
| |||
| ENDURA7 |
|
|
| |||
| ENDURA10 |
|
|
|
|
|
|
| ENDURA D |
|
|
|
|
|
|
| PAG L95 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| NICD14 |
|
|
|
|
|
|
| TYPE A |
|
|
|
|
|
|
C U F | TYPE B |
|
|
|
|
|
|
|
|
| |||||
BATT NEAR END | ON | For setting whether or not to output the | |||||
ALARM | OFF | warning tone when the battery charge is | |||||
C U F |
| nearly depleted. |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| |||||
BATT NEAR END | ON | When this item is set to ON, the warning | |||||
CANCEL | OFF | tone and the warning display which are | |||||
|
| being output can be canceled by pressing | |||||
|
| the MODE CHECK button when the battery | |||||
C U F |
| charge is nearly depleted. |
|
| |||
|
|
|
| ||||
BATT END ALARM | ON | For setting whether or not to output the |
| ||||
| OFF | warning tone when the battery charge is |
| ||||
C U F |
| depleted. |
|
|
|
|
|
|
|
| |||||
BATT REMAIN | 100% | For setting when the remaining charge | |||||
FULL | 70% | display bar on the LCD is to be displayed | |||||
|
| when a digital battery is used. |
|
| |||
|
| 70%: A full charge is indicated with a 70% | |||||
|
| display |
|
|
|
|
|
|
| 100%: A full charge is indicated with a 100% | |||||
C U F |
| display. |
|
|
|
|
|
|
|
|
| ||||
TAPE NEAR END | ON | For setting whether or not to output the |
| ||||
ALARM | OFF | warning tone when the tape is nearly at its | |||||
C U F |
| end. |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| |||||
TAPE NEAR END | 3min | For setting the remaining tape time at which | |||||
TIME | 2min | to sound the warning that the tape has only | |||||
|
| the designated amount of time (2min. or | |||||
C U F |
| 3min.) remaining. |
|
|
|
| |
|
|
| |||||
TAPE END ALARM | ON | For setting whether or not to output the | |||||
| OFF | warning tone when the tape reaches the | |||||
C U F |
| end. |
|
|
|
|
|
|
|
| |||||
TAPE REMAIN/∫ | 5min/∫ | For setting the time of each segment (∫) | |||||
| 3min/∫ | that makes up the remaining time display | |||||
|
| bar on the LCD. |
|
|
|
|
|
|
| 5min: Each segment denotes a remaining | |||||
|
| time of 5 minutes. |
|
| |||
|
| 3min: Each segment denotes a remaining | |||||
C U F |
| time of 3 minutes. |
|
| |||
|
|
|
|
|
|
|
|
126