Chapter 4 Adjustments and settings for recording (continued)
Display item |
| What is displayed | Status when display appears |
|
|
|
|
|
|
|
|
(AUDIO: microphone |
| FRONT: ON/OFF | This indicates the status of the front microphone’s power. |
power status) |
| REAR: ON/OFF | This indicates the menu setting status for the rear microphone’s |
|
|
| power. |
|
|
|
|
(AUDIO: channel |
| FRONT/W.L./REAR | This indicates the input signals and levels for the individual channels. |
input signals and |
| CH1/2/3/4 |
|
levels) |
|
|
|
|
|
|
|
: Camera warning |
| AWB A ACTIVE | This appears during an AWB operation for channel A. |
and message |
| AWB B ACTIVE | This appears during an AWB operation for channel B. |
display area |
| AWB A OK ¢.¢K | This appears when the AWB operation has been completed |
(Displays related to |
|
| satisfactorily for channel A. |
the AWB, ABB and |
| AWB B OK ¢.¢K | This appears when the AWB operation has been completed |
switch operations) |
|
| satisfactorily for channel B. |
|
| AWB BREAK ¢.¢K | This appears when the AWB operation has been forcibly terminated. |
|
| AWB NG | This appears when the AWB operation has not been completed |
|
|
| satisfactorily. The status is indicated on the second line. |
|
| COLOR TEMP LOW | This warns the user that the color temperature is too low. |
|
| COLOR TEMP HIGH | This warns the user that the color temperature is too high. |
|
| LEVEL OVER | This warns the user that the brightness is too high. |
|
| LOW LIGHT | This warns the user that the brightness is too low. |
|
| TIME OVER | This warns the user that the processing could not be executed |
|
|
| within the operation time. |
|
| AWB PRESET ¢.¢K | This appears when the AWB switch is set to PRE or when super gain |
|
|
| is set and AWB cannot be executed. |
|
| CHECK FILTER | This warns the user to recheck the position of the filter selector control |
|
|
| during the AWB operation. |
|
| ABB ACTIVE | This appears during an ABB operation. |
|
| ABB OK | This appears when the ABB operation has been completed satisfactorily. |
|
| ABB BREAK | This appears when the ABB operation has been forcibly terminated. |
|
| ABB NG | This appears when the ABB operation has not been completed |
|
|
| satisfactorily. |
|
| This appears when the BLACK SHADING operation is ready to be | |
|
|
| performed as a result of holding down the ABB switch for a length of |
|
|
| time during an ABB operation. |
|
| This appears during a BLACK SHADING operation. | |
|
| This appears when the BLACK SHADING operation has been | |
|
|
| completed satisfactorily. |
|
| This appears when the BLACK SHADING operation has been forcibly | |
|
|
| terminated. |
|
| This appears when the BLACK SHADING operation has been not | |
|
|
| completed satisfactorily. |
|
|
|
|
(Switch selection |
| WHITE: # ¢.¢K | This appears when the position of the WHITE BAL switch has been |
displays) |
|
| changed. “A,” “B” or “PRE” appears at #. |
|
| AUTO KNEE: ON/OFF | This appears when the AUTO KNEE switch has been set to ON or OFF. |
|
| GAIN: ¢¢dB | This appears when the gain has been selected using the GAIN |
|
|
| selector switch or USER button. |
|
| SS: 1/¢¢¢¢ | This indicates the shutter speed value when the shutter speed has |
|
|
| been selected. |
|
| SS: 1 1/¢¢¢¢ | This appears when synchro scan has been selected as the shutter |
|
|
| speed. |
|
| CC: ¢¢¢¢ ¢¢K | This appears when the CC filter setting has been selected. |
|
| ND: ¢ | This appears when the ND filter setting has been selected. |
|
| EXTENDER: ON/OFF | This appears when the lens extender has been set to ON or OFF. |
|
| IRIS: ¢¢ F ¢ ¢ | This appears when the iris overwrite correction value has been changed. |
|
|
|
|
(LOW LIGHT |
| LOW LIGHT | This appears when the brightness has dropped. |
warning display) |
|
|
|
(Y GET value) |
|
|
|
| ¢¢¢.¢% | With the Y GET ON setting, the output brightness level near the | |
|
|
| center marker is displayed as “%.” |
|
|
|
|
(MARKER display) |
| MKR: A/B/OFF | This indicates the type of marker presently being displayed. |
|
|
|
|
52