Chapter 4 Adjustments and settings for recording (continued)
The setting data can be written in the scene file area of the unit’s internal memory and the data written can be read from this area. Up to four scene files can be registered. By using this data, the appropriate setup statuses can be established speedily.
At the factory, the unit’s default statuses were set in
1 Perform a menu operation to open the <SCENE> screen.
2 Turn the JOG dial button to move the arrow (cursor) to the SCENE SEL item.
3 When the JOG dial button is pressed, the scene file number starts flashing. Turn the JOG dial button to select the scene file in which data is to be saved.
< SCENE > |
|
READ USER DATA |
|
# SCENE SEL | :1 |
READ
WRITE
RESET
TITLE1 : ********
TITLE2 : ********
TITLE3 : ********
TITLE4 : ********
4 Press the JOG dial button to enter the scene file.
5 Turn the JOG dial button to move the arrow (cursor) to the WRITE item.
< SCENE >
READ USER DATA
SCENE SEL ;1
READ
#WRITE RESET
TITLE1 : ********
TITLE2 : ********
TITLE3 : ********
TITLE4 : ********
6 When the JOG dial button is pressed, the following message appears.
WRITE?
YES
#NO
7 Turn the JOG dial button to move the arrow (cursor) to YES, and press the JOG dial button.
The setting data is now stored in the scene file area of the unit’s internal memory.
8 Press the MENU button to exit the menu operations.
70