1. Parts and their functions
Positioner (POSITIONER) [X/Y]
These are used when performing the settings below. ppPinP1, PinP2 position settings
ppWipe start position setting
Target patterns:
WIPE1: 5
WIPE2: 4, 5, 6, 7
SQ1: 5
SQ2: 4, 5, 6, 7
Refer to
ppFlying key position setting
ppChroma key marker position setting
In each case, the settings take effect only when the following menu items have been selected.
Note
Z
X/Y
POSITIONER
Rotary encoder [Z]
This is used to set the PinP size, flying key size or to select the chroma key area.
In each case, the settings take effect only when the following menu items have been selected.
During the time it takes for the unit to start up after its power is turned on, the unit detects the positions of the positioners and sets them to their center positions.
Do not touch the positioners until the unit has started up.
| Positioner | Rotary encoder | Valid menu | |
| X/Y | Z | Switch | |
|
| |||
PinP1, PinP2 | Position adjustments | Size adjustments | Hold switch down to restore | All PinP1 and PinP2 menus |
|
| (size increased by rotating the | initial values (X/Y, Z). |
|
|
| encoder clockwise and reduced |
|
|
|
| by rotating it counterclockwise) |
|
|
WIPE (BKGD) | Start position | — | Hold switch down to restore | Background/WIPE Position |
| adjustments |
| initial values (X/Y). | Background/SQ Position |
WIPE (KEY) | Start position | — | Hold switch down to restore | Key/WIPE Position |
| adjustments |
| initial values (X/Y). | Key/SQ Position |
Chroma key | Selection position | Selected area size adjustments | Execute sampling | Chroma Key/Sample1 |
| adjustments | (size increased by rotating the |
| Chroma Key/Sample2 |
|
| encoder clockwise and reduced |
|
|
|
| by rotating it counterclockwise) |
|
|
Flying key | Position adjustments | Size adjustments | Hold switch down to restore | Key: Flying Key |
|
| (size increased by rotating the | initial values (X/Y, Z). |
|
|
| encoder clockwise and reduced |
|
|
|
| by rotating it counterclockwise) |
|
|
25