11.2.5Wiring Stripping and connecting requirement

11.2.5Wiring Stripping and connecting requirement

11.2.5.1Cutting and flaring the piping

1Please cut using pipe cutter and then remove the burrs.

2Remove the burrs by using reamer. If burrs are not removed, gas leakage may be caused. Turn the piping end down to avoid the metal powder entering the pipe.

3Please make flare after inserting the flare nut onto the copper pipes.