Panasonic Indoor Unit Outdoor Unit CS-E9NKUAW CS-E12NKUAW CU-E9NKUA CU-E12NKUA Malfunction Caused

Models: Indoor Unit Outdoor Unit CS-E9NKUAW CS-E12NKUAW CU-E9NKUA CU-E12NKUA

1 90
Download 90 pages 44.12 Kb
Page 71
Image 71
16.4.24F96 (IPM Overheating)

16.4.24F96 (IPM Overheating)

Malfunction Decision Conditions

During operating of cooling and heating, when IPM temperature data (212°F) is detected by the IPM temperature sensor.

Malfunction Caused

šIPM overheats due to short circuit of hot discharge air flow.

šIPM overheats due to defective of outdoor fan motor.

šIPM overheats due to defective of internal circuitry of IPM.

šIPM overheats due to defective IPM temperature sensor.

Troubleshooting

71

Page 71
Image 71
Panasonic Indoor Unit Outdoor Unit CS-E9NKUAW CS-E12NKUAW CU-E9NKUA CU-E12NKUA 16.4.24F96 IPM Overheating, Troubleshooting