16.4.26F98 (Input Over Current Detection)

16.4.26F98 (Input Over Current Detection)

Malfunction Decision Conditions

During cooling and heating operation, when an input over-current (16.8A) is detected by checking the input current value being detected by current transformer (CT) with the compressor running.

Malfunction Caused

šOver-current due to compressor failure.

šOver-current due to defective outdoor unit PCB.

šOver-current due to defective inverter main circuit electrolytic capacitor.

šOver-current due to excessive refrigerant.

Troubleshooting