16.4.23F95 (Cooling High Pressure Abnormality)

16.4.23F95 (Cooling High Pressure Abnormality)

Malfunction Decision Conditions

During operation of cooling, when outdoor unit heat exchanger high temperature data (141.8°F) is detected by the outdoor pipe temperature sensor.

Malfunction Caused

šOutdoor pipe temperature rise due to short circuit of hot discharge air flow.

šOutdoor pipe temperature rise due to defective of outdoor fan motor.

šOutdoor pipe temperature rise due to defective outdoor pipe temperature sensor.

šOutdoor pipe temperature rise due to defective outdoor unit PCB.

Troubleshooting