šCT defective

16.4.5H16 (Outdoor Current Transformer Open Circuit)

Malfunction Decision Conditions

šA current transformer (CT) is detected by checking the compressor running frequency (≥ rated frequency) and CT detected input current (less than 0.65A) for continuously 20 seconds.

Malfunction Caused

šCT defective

šOutdoor PCB defective

šCompressor defective (low compression)