:.-.......-.-----until the desired CO number appears

until the desiredflash timing appears

:.

[34][NEXT] [NEI(T] [SELECT] [MEMYRY] [END]

or

[34][NEXT] [A] [SELECT] [MEMORY] [END]

I~~~~~~~~~-._.._.~-~~-~A=[*]:-~---~~ to assign the same on all 6 CO’s --/-

Description

The timing of the hookswitch flash signal must be within the requirements from your Central Office.

There are three choices available 0.3, 0.6 or 0.9 second.

Programming

1.Dial (34).

“FLASH TIME SET” will be displayed.

2.Press the NEXT button.

“ENTER CO NO” will be displayed.

3.Press the NEXT button.

“CO 1: 600 MS” will be displayed and “600 MS” will blink.

4.Repeat pressing the SELECT button until the desired value is displayed.

5.Press the MEMORY button. The LCD will stop blinking.

6.Repeat steps 3 to 5, to set the hookswitch timing of the other CO’s.

7.To return to the initial program mode, press the END button.

Conditions

0 When you start the programming from step I, you may dial the desired CO number instead of the NEXT button at step 3.

OThe PREV button allows you to go to the previous CO for displaying the hookswitch flash timing.

Example:

l O.3 set on all 6 CO= .

[34] [NEXT] [++I [SELECT] [SELECT] [MEMORY]

[END1

Programming Table

See page 6-20.

3-49

Page 72
Image 72
Panasonic KX-T61610 manual Next Neit Select Memyry END Next a Select Memory END, Next ++I Select Select Memory