On-screen display

Lamp indicator warning

 

 

light

 

Displayed for 30

 

More than 1 800 hours

seconds. Pressing any

 

button will clear the

Illuminates red during

 

display.

 

image projection and

 

 

 

Remains displayed until

standby mode.

More than 2 000 hours

any button is pressed.

 

Lamp unit replacement procedure

NOTE:

BIf the lamp usage time has passed 2 000 hours (when LAMP POWER has been set to “HIGH”), the projector will switch to standby mode after approximately 10 minutes of operation. The steps ) to - on the next page should thus be completed within 10 minutes.

'Install the lamp unit cover, and then use a Phillips screwdriver to securely tighten the lamp unit cover fixing screws.

NOTE:

BBe sure to install the lamp unit and the lamp unit cover securely. If they are not securely installed, it may cause the protection circuit to operate so that the power cannot be turned on.

(Insert the mains lead plug into the mains socket and then press the MAIN POWER switch.

NOTE:

BIf the POWER indicator on the

projector does not illuminate red

when the MAIN POWER switch

is turned on, turn the MAIN

POWER switch off again, unplug

+Select the “LAMP RUN TIME” by pressing the F or G buttons.

OPTION

PREVIOUS PAGE ^

 

 

FRONT/REAR

FRONT

REAR

DESK/CEILING

DESK

CEILING

FAN CONTROL

STANDARD

HIGH

LAMP POWER

LOW

HIGH

LAMP RUN TIME

 

1820 H

FUNC1

MUTE

KEYSTONE

CONTROL KEY

OFF

ON

AUTO POWER OFF

DISABLE

SELECT:[^][@]

ENTER:[ENTER]

 

ESC:[MENU]

,Press and hold the ENTER button for approximately 3 seconds.

LAMP TIME RESET

Power OFF

OK

CANCEL

#Turn off the MAIN POWER switch according to the procedure given in “Turning off the power” on page 25, and then disconnect the mains lead plug from the mains socket and check that the area around the lamp unit has cooled down.

$Use a Phillips screwdriver to turn the lamp unit cover fixing screws at the bottom of the projector, and then remove the lamp unit cover from the projector.

Lamp unit cover

Lamp unit cover fixing screws

%Use a Phillips screwdriver to loosen the two lamp unit fixing screws until the screws turn freely. Then hold the handle of the lamp unit and gently pull it out from the projector.

Lamp unit fixing screws

Handle

&Insert the new lamp unit while making sure that the direction of insertion is correct, and then use a Phillips screwdriver to securely tighten the lamp unit fixing screws.

the mains lead from the electrical

outlet, and check that the lamp

unit and the lamp unit cover are

securely installed. Then turn the

MAIN POWER switch back on.

)Press the POWER button so that a picture is projected onto the screen.

*Press the MENU button to display the MENU screen, and select “OPTION” by pressing the I or H buttons.

OPTION

OSD

OFF

ON

AUTO SEARCH

OFF

ON

AUTO SIGNAL

OFF

ON

AUTO KEYSTONE

OFF

ON

RGB2 SELECT

INPUT

OUTPUT

RGB/YPBPR

RGB

YPBPR

VGA60/525P

VGA60

525P

BLACKBORD

OFF

ON

BACK COLOR

BLUE

BLACK

 

 

 

NEXT PAGE @

 

 

SELECT:[^][@]

 

 

ADJUST:[{][}]

ESC:[MENU]

The “LAMP TIME RESET” will be displayed.

-Select “OK” by pressing the I or H buttons and press the

ENTER button.

NOTE:

BIf “CANCEL” is selected in step -, the operation for resetting the lamp time will be cancelled.

.Turn off the power.

This will reset the cumulative usage time for the lamp unit to zero.

Refer to page 25 for details on how to turn off the power.

Care and maintenance

56-ENGLISH

ENGLISH-57

Page 29
Image 29
Panasonic PT-L735E, PT-L735NTE Lamp unit replacement procedure, + Select the Lamp RUN Time by pressing the F or G buttons