Connections
IR IN/OUT (infrared signal) connection
Connect between the IR OUT terminal of the ¿rst display and the IR IN terminal of the second display with a 3.5 mm stereo mini plug.
Infrared signals will be sent from the ¿rst display to the second display.
First display | Second display |
| Third display |
* | * |
* Stereo mini plug (M3)
IR of the second display will not work in this connection.
It is possible to con¿gure a daisy chain connection by repeating the connection above.
CHARGE Terminals connection
Power can be supplied when a separately sold stick PC or such other device is connected.
Note:
To supply power, be sure to set “5V Charge” to “On” in the “Options” menu. (see page 44)
Pin Layout and Signal Names of CHARGE Terminal
1 +5V
2NC
3NC
4 GND
1 2 3 4
stick PC
USB cable
Up to 5V/500 mA power can be supplied to an external device when an image is received.
ƔIf current exceeding the supply capacity Àows, output will be shut off and the following message will appear. “5V CHARGE OUT overload. Please remove cable, then turn the display off/on.”
In this case, turn the power off and on with the remote control, etc.
Note:
If there is dust in a terminal, the protection circuit may function. Cover the terminals, such as with tape, when not in use.
(The terminals are protected by tape when shipped from the factory.)
13