Options Adjustments

RS-232C/LAN Information Timing

Set up the informing manner for no signal or temperature rising.

While RS-232C controls: Warning or error message sent on the display automatically.

While LAN controls: Acquire the warning or error message from the display.

 

Options

2/3

 

 

 

 

 

 

Off-timer function

Enable

 

 

Initial Power Mode

Normal

 

 

ID select

0

 

 

 

 

Remote ID

Off

 

 

Serial ID

Off

 

 

Studio W/B

Off

 

 

LAN Control Protocol

Protocol 1

 

 

RS-232C/LAN Information Timing

 

 

Press ACTION () button

RS-232C/LAN Information Timing

 

 

 

 

No Signal Warning

On

 

No Signal Warning Timing

5min

 

 

 

 

No Signal Error

On

 

No Signal Error Timing

10min

 

 

 

 

Temperature Warning

On

 

Temperature Warning Value

55°C

 

Temperature Warning Release Value

52°C

1

select

2

adjust

No Signal Warning

If set to “On”, the display sends out the no signal warning.

No Signal Warning Timing

Set up the detecting time for no signal warning.

No Signal Error

If set to “On”, the display sends out the no signal error.

No Signal Error Timing

Set up the detecting time for no signal error.

The warning of “No Signal Warning” and the error of “No Signal Error” are not sent when the no signal state is detected through any of the following functions:

No Signal power off: Enable, PC Power management, DVI-D Power management, HDMI1 Power management, HDMI2 Power management (see page 32)

Setting Example

No Signal Warning Timing: 5 minutes

No Signal Error Timing: 10 minutes

PC Power management: On (30 seconds)

If there is no signal when PC IN is input, “PC Power management” is activated ¿rst and the Display enters the standby mode.

Note:

The “No Signal Error Timing” cannot be set shorter than “No Signal Warning Timing”.

Temperature Warning

If set to “On”, the display sends out the warning temperature.

Temperature Warning Value

Set up the detecting temperature for temperature warning.

Temperature Warning Release Value

Set up the temperature to release the temperature warning.