Introduction and Installation

Wiring schematic diagram

 

Door station

Terminal box

 

 

(4-conductor wiring)

 

 

 

D1 D2

(Non polar)

PBX

(Example: KX-TDA50)

Monitor station

D1

 

D2

 

P1

 

P2

(Non polar)

S1

S2

(Non polar)

 

Power cable

Door opener

AC adaptor

 

Power cord

 

Note:

LThis door opener wiring schematic diagram is only an example. Refer to the wiring instructions provided with your door opener and PBX for details.

LRefer to the technical data on page 30 when connecting to a door opener.

Power cable/wire type and distance

LPower cable (between the monitor station and the AC adaptor): Type: Ф1.2 Fire alarm cable 16 AWG

Distance: Maximum 30 m (about 98 feet)

LWire (between the monitor station and the door station): Type: General cable CAT-3 24 AWG

Distance: Maximum 100 m (about 328 feet)

Loop resistance: 18.4 or lower

LWire (between the monitor station and PBX): Type: General cable CAT-3 24 AWG Distance: Maximum 100 m (about 328 feet)

11

Page 11