Image 41
If the network operator were simultaneously configuring multiple ports, the following screen would instead appear and any values not overwritten would be left unchanged.

PANDUIT® DPoE™ Power Patch Panel User’s Guide

Issue 2.2

 

Part Number: PN378A

If the network operator were simultaneously configuring multiple ports, the following screen would instead appear and any values not overwritten would be left unchanged.

Administration Control - This setting {on/off} allows the network operator to control whether each individual port is sourcing PoE power. If this field is set to off, the port acts like any port on a non-powered patch panel rather than a PoE port. This enables the network operator to mix non-powered or locally powered devices in the same panel as PoE devices. The factory default setting for this field is ON.

Power Priority - This setting {low, high, critical} indicates whether the importance of maintaining PoE power to this port in low-power situations. This field is used in coordination with a higher-level Network Management System (if available).

PD Type - This free-form field allows the network operator to enter information on the Powered Device (PD), such as the type of device (IP-phone, camera etc.).

Work Area Location - These free-form fields allows the network operator to enter information such as the location where the device is located.

Legacy Detection – This setting {enabled, disabled} allows the network operator to specify whether this port is connected to a Cisco legacy PoE device. If this field is set to enabled, the DPoE™ Power Patch Panel port will transmit Cisco-standard power rather than the IEEE 802.3af-2003 compliant power.

Export Log

This task, like the Export Panel Information capability, allows the network operator to copy the Log Messages from the currently selected port, rack or the entire network of DPoE™ Power Patch Panels to an external file.

The Export Log button on the tool bar on the View Panel Screen provides an easy mechanism to perform this task.