5.9.2 Delete Encapsulation

To delete encapsulation, select a VCC entry and then click on the Delete Encap button.

5.9.3 Add a VCC

To add a VCC entry, complete the following steps.

STEP 1: Click on the Add VCC button. The VCC screen appears.

STEP 2: Enter values for the parameters (explained below).

STEP 3: Click on the Apply button at the bottom of the page.

VPI

Virtual Path Identifier (VPI) that identifies this ATM

 

connection. The valid range is 0 to 4095.

 

 

VCI

Virtual Channel Identifier (VCI) that identifies this ATM

 

connection. The valid range is 0 to 65,535.

 

 

Peak Cell rate

Defines the fastest rate a user can send cells to the

(cells/sec)

network. It is expressed in cells per second.

 

 

Average Cell rate

Defines the maximum sustainable average rate a user can

(cells/sec)

send cells to the network. It is expressed in cells per

 

second. This specifies the bandwidth utilization. This value

 

must always be less than or equal to the Peak Cell Rate.

 

 

Burst size (cells)

Maximum number of cells the user can send at the peak

 

rate in a burst, within a sustainable rate.

 

 

CDVT (cells)

Constrains the number of cells the user can send to the

 

network at the maximum line rate.

 

 

Type

Select data or voice

 

 