Patton electronic 1082, 144, I Switches S1-1 and S1-2 Data Rate, S1-3 Setting S1-4, S1-5 Setting

Models: 1082, 144, I

1 28
Download 28 pages 54.89 Kb
Page 13
Image 13

Note When setting the 1082 for SNMP Management, the DTE rate switches (S1-1,S1-2, and S2-1) must be also set to the ON posi- tion. Therefore, to set a 1082 unit SNMP Mangagement mode, the following switches have to be at the ON position, S1-1, S1-2, S2-1.

Switches S1-1 and S1-2: Data Rate

Use switches S1-1 and S1-2 to configure the asynchronous or synchro- nous data rate of the Model 1082/I and Model 1082/144/I. Each setting represents one synchronous data rate and one asynchronous data rate.

S1-1

S1-2

Sync Data Rate

Async. Data Rate

 

 

 

 

On

On

32 kbps

Reserved

Off

On

56 kbps

Reserved

 

 

 

 

On

Off

64 kbps

Reserved

 

 

 

 

Off

Off

128 kbps (see note)

0–38.4 kbps

 

 

 

 

Off

Off

144 kbps or 19.2 kbps (see note)

Reserved

 

 

 

 

Note The Model 1082/I can also operate at the 19.2 kbps synchro- nous rate, and the Model 1092/144/I can also operate at the 144 kbps synchronous rate. To operate at these rates, set Switches S1-1 and S1-2 both to the OFF position and Switch S2-1 to the ON position (see “Configuring DIP switch “S2”” on page 152 for a description of Switch S2-1).

If the S2-1 switch is positioned in the OFF position, the 128 kbps sync data rate/0–38.4 kbps async data rate option is selected.

Switch S1-3 and S1-4: Must be set to the ON position (Reserved).

S1-3

Setting

S1-4

Setting

 

 

 

 

On

Reserved

On

Reserved

Switch S1-5: Asynchronous/Sync Operation

Use Switch S1-5 to configure the Model 1082 for async/sync operation. Switch S1-5 must be set in the Off position. There is no other valid set- ting.

S1-5

Setting

 

 

Off

Async/Sync

13

Page 13
Image 13
Patton electronic 1082, 144, I Switches S1-1 and S1-2 Data Rate, S1-1 S1-2 Sync Data Rate Async. Data Rate, S1-5 Setting