Receive Alarm Indication [RAI] indicates that the local unit is receiv- ing a Yellow Alarm. This alarm is sent by the remote unit or the central office when it loses the received signal. This indicates the local unit’s transmitted signal is not reaching the remote unit.
Rx Level The Model 2710 displays the current received signal strength in dB. There are four level ranges detected:
+2 to
Valid Interval Count & Current Interval Time
The Valid Interval Count and Current Interval Time display the number of valid 15 minute intervals in the last 24 hours and the num- ber of seconds which have elapsed in the current interval, respectively. The Valid Interval Count saturates at the count of 96 (96 * 15min = 24 hours), while the Current Interval Time rolls over after 900 counts. When the counter rolls over, it is reset to zero, and the Interval Counter is incremented by one if the count is less than 96.
Valid Interval Count: [96]
Current Interval Time: [899]
Error Counters
These error counters give a
|
|
|
|
|
|
| ERR SEC: | 0 | 0 | Errored Seconds in Current Interval.... |
|
| UAS SEC: | 557 | 209 | Unavailable Seconds |
|
| SE SEC: | 0 | 0 | Severely Errored Seconds |
|
| BE SEC: | 0 | 0 | Bursty Errored Seconds |
|
| LOF SEC: | 0 | 0 | Loss of Frame Error Seconds |
|
|
|
|
|
|
|
|
|
|
|
|
|
Rx PRM
The
Rx PRM: 00010000000300023289
Current DIP Switch Settings
The Switch settings are displayed here to facilitate troubleshooting your unit without opening up the unit first.
27 | 28 |