Patton electronic 2710 PATTON NETLINK-T1 MODEL CABLE RECOMMENDATIONS, Wire Gauge, Capacitance

Models: 2710

1 23
Download 23 pages 33.47 Kb
Page 21
Image 21

APPENDIX B

PATTON NETLINK-T1™ MODEL 2710

CABLE RECOMMENDATIONS

The Patton NetLink T1™ Series has been performance tested by Patton technicians using twisted-pair cable with the following charac- teristics:

Wire Gauge

Capacitance

Resistance

19 AWG

83nf/mi or 15.72 pf/ft.

.0163 Ohms/ft.

22 AWG

83nf/mi or 15.72 pf/ft.

.0326 Ohms/ft.

24 AWG

83nf/mi or 15.72 pf/ft.

.05165 Ohms/ft.

To gain optimum performance from the Model 2710 Series, please keep the following guidelines in mind:

Always use twisted pair wire—this is not an option.

Use twisted pair wire with a capacitance of 20pf/ft or less.

Avoid twisted pair wire thinner than 26 AWG (i.e. avoid AWG numbers higher than 26)

Use of twisted pair with a resistance greater than the above specifications may cause a reduction in maximum distance obtain- able. Functionality should not be affected.

Many environmental factors can affect the maximum distance obtainable at a particular site.

APPENDIX C

PATTON NETLINK-T1™ MODEL 2710

FACTORY REPLACEMENT PARTS

AND ACCESSORIES

Patton Model #

 

Description

2710/CM/120

T1

Nx64 CSU/DSU(M/34 Male, 120VAC)

2710/CM/UI

T1

CSU/DSU (V.35 M/34 Male, UI)

10 - 09F

6 Foot Control Port Cable, 25 mm to

 

DB9F

07M2710

User Manual

39

40

Page 21