To unmount indoor unit

Press the 2 Manual background marks on the lower part of the indoor unit and unlatch the tabs. Then lift the indoor unit and unmount. (Fig. 42)

3-10. Drain Hose

a)The drain hose should be slanted downward to the outdoors. (Fig. 43)

b)Never form a trap in the course of the hose.

c)If the drain hose will run in the room, insulate the hose with insulation* so that chilled condensation will not damage furniture or floors. (Fig. 44)

* Foamed polyethylene or its equivalent is recom- mended.

 

 

Do not supply power to the

 

WARNING

 

unit or operate it until all

 

 

 

 

 

 

tubing and wiring to the out-

 

 

side unit are completed.

 

Risk of Electric Shock

 

 

 

Push

Fig. 42

 

Slant

Indoor

Drain

unit

hose

 

Fig. 43

Condensation

Insulation material (Locally purchased) must be used.

Fig. 44