Manuals
/
Panasonic
/
Household Appliance
/
Air Conditioner
Panasonic
CU-KS18NKU
service manual
Dimensional Data, Indoor Unit CS-KS18NKU
Models:
CS-KS18NKU
CU-KS18NKU
1
22
122
122
Download
122 pages
36.27 Kb
19
20
21
22
23
24
25
26
<
>
Specs
Electrical Characteristics
Install
Refrigerant Flow Diagram
Timer backup
Wired Remote Controller
Dimension
Maintenance
Method of Self-Diagnostics
WHT 1P-CONNECTORWHT
Page 22
Image 22
3. DIMENSIONAL DATA
Indoor Unit
CS-KS18NKU
CS-KS24NKU
CS-KS24NKU
CS-KS18NKU
Unit: inch(mm)
(852-0-0010-216-00-0)
22
Page 21
Page 23
Page 22
Image 22
Page 21
Page 23
Contents
DC Inverter Split System AIR Conditioner
Safety Precautions
Prohibit
Table of Contents
Appendix a
CS-KS24NKU + CU-KS24NKU
Operating Range
Models CS-KS18NKU + CU-KS18NKU
Models CS-KS18NKU + CU-KS18NKUA
CS-KS18NKU
Specifications
Unit Specifications
CU-KS18NKU
208V
CS-KS24NKU
CU-KS24NKU
12.1
CU-KS18NKUA
15 1.2 to
Outdoor Unit CU-KS24NKUA 230V
Dimen
CU-KS24NKUA
Indoor Unit
Major Component Specifications
Indoor Unit CS-KS18NKU
Indoor Unit CS-KS24NKU
CB-CS-KS24NKU
Outdoor Unit
Outdoor Unit CU-KS18NKU
Outdoor Unit CU-KS24NKU
Outdoor Unit CU-KS18NKUA
Outdoor Unit CU-KS24NKUA
CS-KS18NKU CS-KS24NKU
Other Component Specifications
CU-KS18NKU CU-KS24NKU CU-KS18NKUA CU-KS24NKUA
Dimensional Data
23-15/165-11/32
852-0-0010-119-00-0
Insulation of Refrigerant Tubing
Refrigerant Flow Diagram
Refrigerant Flow Diagram
CS-KS24NKU CU-KS18NKUA CU-KS24NKUA
Temperature Charts
Performance Data
Indoor Unit CS-KS18NKU Outdoor Unit CU-KS18NKUA
Indoor Unit CS-KS24NKU Outdoor Unit CU-KS24NKU
Indoor Unit CS-KS24NKU Outdoor Unit CU-KS24NKUA
Cooling Capacity
Power Supply 230V Single Phase 60Hz Cooling Capacity
Outdoor Unit CU-KS18NKU / CU-KS18NKUA
Outdoor Unit CU-KS24NKU / CU-KS24NKUA
Cooling Capacity Low Ambient
SHC
15,690 20,420
Air Throw Distance Charts
Cooling
Electrical Characteristics
Electrical Data
CS-KS24NKU
Indoor Unit CS-KS18NKU CS-KS24NKU
Electric Wiring Diagrams
8FA2-5251-11000-2
Outdoor Unit CU-KS18NKU CU-KS18NKUA
BLK
RED
WHT 1P-CONNECTORWHT
Maintenance
Address Setting of the Remote Control Unit
How to Disconnect
How to Connect
Emergency operation
Functions
Operation Functions
PAM- control
Timer backup
Lamp colors
Freeze prevention
Compressor discharge temperature control
Protective Functions
CT Peak current cut-off control
Precautions before Performing Inspection or Repair
Troubleshooting Before Calling for Service
Method of Self-Diagnostics
Self-diagnostics Lamps
Code Diagnosis Contents
Replace the controller
Normal
Replace the circuit board or the fuse
Checking the Indoor and Outdoor Units
Using the TEST/T-RUN terminals
Checking the indoor unit Control Check items unit operation
Off Blinking Illuminated
Serial Communication Error Identification Procedure
Before the Operation
Condition E01
From the previous page a
Condition E12
Trouble Diagnosis of Fan Motor
Indoor Fan Motor
Outdoor Fan Motor
CU-KS24NKU / CU-KS24NKUA
Noise malfunction
Noise Malfunction and Electromagnetic Interference
Electromagnetic interference
Measurement of Insulation Resistance
Power Supply Cord
Checking Electrical Components
Measurement of Insulation Resistance for Electrical Parts
Checking Continuity of Fuse on PCB Assy
What is New Refrigerant R410A?
Refrigerant R410A Special Precautions When Servicing Unit
Characteristics of New Refrigerant R410A
Characteristics
Checklist before Servicing
Tubing Installation Procedures
Tools Specifically for R410A
Procedure for Replacing Compressor
Case of Compressor Malfunction
Damage to the compressor
Never charge a large amount
Unit. This may cause
Amount in the charging cylinder is less than 20%
Welding leaking points
Case Refrigerant is Leaking
Recharging
Retro-Fitting Existing Systems
When Tubes are Extended
Charging Additional Refrigerant
Use of Existing Units
Appendix a Operating Instructions
Operating Instructions Split System Air Conditioner
Safety Precautions
Features
Contents
Product Information
Safety Instructions
Installation Location
Electrical Requirements
Page
Indoor Unit
Names of Parts
Outdoor Unit
Unit Display and Operation Button
Green and FAN green mode
Quiet lamp
Remote Controller Display
On Time
Remote Controller
Hour OFF Timer
OFF Time
Cool
Temp
DRY
FAN
ACL button ALL Clear
Using the Remote Controller
How to Install Batteries
Use a thin object such as the tip of a pen to press
Rear Side Hole
To take out the remote controller, pull it forward
Receiver which could block the signal
Controller
Operation with the Remote Controller
Step
Operation with the Remote Controller
Press the ON/OFF operation button
Night Setback Mode
Quiet Mode
Special Remarks
Power failure during operation
Clicking sound is heard from the air conditioner
Example To set to 1030 pm
Setting the Timer
Operation Indication
1030 pm 710 am 1100 am
How to set the on time Example To start operation at 710 am
To cancel a timer program Press the Cancel button
OFF
Cancellation procedure
Using the 1-HOUR OFF Timer
Setting procedure
Operation together with the Daily ON/OFF Repeat Timer
Adjusting the Airflow Direction
Cool Sweep DRY FAN
When the air conditioner is not running
Operation Without the Remote Controller
Care and Cleaning
Cyclically Cooling operation Stop
How to remove the filter 1. Grasp both ends of the air
Groove Pin Air intake grille
Wired Remote Controller
Washing the grille with water
Operating Range
Troubleshooting Before Calling for Service
Trouble Possible Cause Remedy
Specifications
CU-KS18NKU, CU-KS18NKUA CS-KS18NKU
852-6-4190-576-00-0
Installation Instructions Split System Air Conditioner
Contents
Please Read Before Starting
Fins of the outdoor unit. You may get injured
Accidentally
General
Tools Required for Installation not supplied
Accessories Supplied with Unit Table
Optional Copper Tubing Kit
Additional Materials Required for Installation
Installation Site Selection
Avoid
About
Front Back
Baffle Plate for the Outdoor Unit CU-KSxxNKUA models only
Air Intake Baffle
Air Discharge Baffle
Precautions for installation
Remove the Rear Panel from the Unit
How to Install the Indoor Unit
Trical wiring or conduits are
Make a Hole
If Wooden Wall
Install the Rear Panel on the Wall
If Block, Brick, Concrete or Similar Type Wall
How to remove the grille
Remove the Grille to Install the Indoor Unit
How to replace the grille
Wiring Instructions General precautions on wiring
Shape the Indoor Side Tubing
Recommended Wire Length and Diameter
Wiring System Diagram
Wiring Instructions for Inter-unit Connections
For Outdoor Unit For solid core wiring or F-cable
How to connect wiring to the terminal For Indoor Unit
For stranded wiring
Mounting
Right-side tubing
Left-side tubing
Switching drain hose and drain cap
Drain cap
To unmount indoor unit
Do not supply power to
Tubing and wiring to the out
Unit or operate it until all
First refer to . Installation Site Selection
How to Install the Outdoor Unit
Wiring Instructions for the Outdoor Unit
Refrigerant Tubing
Flaring Procedure with a Flare Tool
Use of the Flaring Method
Insulation of Refrigerant Tubing
Connecting Tubing between Indoor and Outdoor Units
Finishing the Installation
To prevent heat loss and wet floors due to dripping of con
Tem. The valve core is similar to
Air Purging
Air Purging with a Vacuum Pump for Test Run
Those used in automobile tires
Page
How to Test Run the Air Conditioner
When opening or closing the service valve stem
Basic Functions of the Service Valves
Basic functions of the service valves are given in below
External diameter of service port R410A 5/16
Remote Controller Installation Position
Service Valve Connections
Mounting on a Wall
Address Switch
Address Setting of the Remote Controller
Page
DC1111-0
Top
Page
Image
Contents