Outdoor Unit CU-KS18NKUA

Control PCB

 

 

 

 

 

 

 

 

 

 

Part No.

 

 

CB-CU-KS18NKUA

 

Controls

 

 

Microprocessor

 

Control Circuit Fuse

 

 

250V 25A

 

 

 

 

 

Compressor

 

 

 

 

 

 

 

 

 

 

Type

 

 

DC Twin Rotary (Hermetic)

 

Compressor Model / Nominal Output

 

 

C-6RVN93H0M / 1,050W

 

Compressor Oil ... Amount

Pints (cc)

FV50S ... 0.74 (350)

 

Coil Resistance (Ambient Temp. 68 °F (20 °C)) Ohm

R - S : 0.482

 

 

 

 

 

S - T : 0.482

 

 

 

 

 

T - R : 0.482

 

Safety Device

 

 

 

 

 

CT (Peak current cut-off control)

Yes

 

 

Compressor Discharge Temp. Control

Yes

 

 

Operation cut-off control in abnormal ambient Temp.

Yes

 

 

Overload Relay

 

Model

CS-7L115

 

 

 

Operation Temp.

Open : 239 °F (115 °C), Close : 203 °F (95 °C)

 

Run Capacitor

 

Micro F

-

 

 

 

 

VAC

-

 

Crankcase Heater

 

 

-

 

 

 

 

 

 

Fan

 

 

 

 

 

 

 

 

 

 

Type

 

 

Propeller

 

Q'ty ... Dia.

inch (mm)

1 ... D16-17/32 (D420)

 

 

 

 

 

Fan Motor

 

 

 

 

 

 

 

 

 

 

Type

 

 

DC Motor

 

Model ... Q'ty

 

 

SIC-67FV-F460-1 ... 1

 

No. of Poles

 

 

8

 

Rough Measure RPM (Cool)

 

 

820

 

Nominal Output

 

W

50

 

Coil Resistance

 

Ohm

RED - WHT : 77.5

 

(Ambient Temp. 68 °F (20 °C))

 

 

WHT - BLU : 77.5

 

 

 

 

 

BLU - RED : 77.5

 

 

 

 

 

 

 

Safety Device

 

 

 

 

 

Type

 

 

Internal Controller

 

 

Over- Current Protection

 

 

Yes

 

Run Capacitor

 

Micro F

-

 

 

 

 

VAC

-

 

 

 

 

 

 

Heat Exchanger Coil

 

 

 

 

 

 

 

 

 

 

Coil

 

 

Aluminum Plate Fin / Copper Tube

 

Rows

 

 

2

 

Fins per inch

 

 

21.2

 

Face Area

 

ft2 (m2)

5.49 (0.510)

 

 

 

 

External Finish

 

 

Acrylic baked-on enamel finish

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

19

Page 19
Image 19
Panasonic CS-KS18NKU service manual Outdoor Unit CU-KS18NKUA