Panasonic CS-KS18NKU, CU-KS18NKU service manual CS-KS24NKU, CU-KS24NKUA

Models: CS-KS18NKU CU-KS18NKU

1 122
Download 122 pages 36.27 Kb
Page 33
Image 33
Manual background

Indoor Unit

:

CS-KS24NKU

Outdoor Unit

:

CU-KS24NKUA

Power Supply :

230V Single Phase 60Hz

< Cooling Capacity (Low Ambient) >

RATING CAPACITY:

24,200 BTU/h

 

AIR FLOW RATE:

659 CFM

INDOOR

 

 

 

OUTDOOR

 

 

 

 

ENT. TEMP. oF (oC)

 

 

 

AMBIENT TEMP. oF (oC)

 

 

WB

DB

 

0

5

15

25

 

35

45

55

 

 

 

(-17.8)

(-15.0)

(-9.4)

(-3.9)

 

(1.7)

(7.2)

(12.8)

 

 

TC

21,090

21,110

20,980

21,210

 

21,150

21,090

21,140

 

72 (22.2)

SHC

15,690

15,690

15,690

20,420

 

15,690

15,690

15,690

59

76 (24.4)

SHC

17,730

17,730

17,730

21,210

 

17,860

17,730

17,730

(15.0)

80 (26.7)

SHC

19,910

19,910

19,910

21,210

 

19,910

19,910

19,910

 

84 (28.9)

SHC

21,090

21,110

20,980

21,210

 

21,150

21,090

21,140

 

88 (31.1)

SHC

21,090

21,110

20,980

21,210

 

21,150

21,090

21,140

 

 

TC

20,960

21,020

21,030

21,460

 

21,460

21,470

21,630

 

72 (22.2)

SHC

12,740

12,740

12,740

20,420

 

13,000

13,000

13,130

63

76 (24.4)

SHC

14,790

14,920

14,920

21,460

 

15,050

15,050

15,170

(17.2)

80 (26.7)

SHC

16,970

16,970

16,970

21,460

 

17,220

17,220

17,350

 

84 (28.9)

SHC

19,010

19,140

19,140

21,460

 

19,270

19,270

19,400

 

88 (31.1)

SHC

20,960

21,020

21,030

21,460

 

21,320

21,320

21,450

 

 

TC

20,600

20,700

20,890

21,570

 

21,640

21,750

22,020

 

72 (22.2)

SHC

9,800

9,800

9,930

20,420

 

10,180

10,310

10,310

67

76 (24.4)

SHC

11,850

11,850

11,970

21,570

 

12,230

12,360

12,490

(19.4)

80 (26.7)

SHC

14,020

14,020

14,150

21,570

 

14,410

14,530

14,660

 

84 (28.9)

SHC

16,070

16,070

16,200

21,570

 

16,580

16,580

16,710

 

88 (31.1)

SHC

18,120

18,250

18,250

21,570

 

18,630

18,630

18,760

 

 

TC

19,950

20,090

20,520

21,510

 

21,680

21,880

22,310

 

72 (22.2)

SHC

6,600

6,720

6,850

20,420

 

7,240

7,360

7,490

71

76 (24.4)

SHC

8,770

8,770

8,900

21,510

 

9,410

9,410

9,540

(21.7)

80 (26.7)

SHC

10,820

10,950

11,080

21,510

 

11,460

11,590

11,720

 

84 (28.9)

SHC

13,000

13,000

13,130

21,510

 

13,640

13,640

13,890

 

88 (31.1)

SHC

15,050

15,050

15,300

21,510

 

15,690

15,690

15,940

 

 

TC

19,060

19,240

19,940

21,270

 

21,540

21,860

22,440

75

76 (24.4)

SHC

5,700

5,830

6,080

21,270

 

6,600

6,600

6,850

(23.9)

80 (26.7)

SHC

7,880

8,000

8,130

21,270

 

8,770

8,770

9,030

 

84 (28.9)

SHC

9,930

10,050

10,310

21,270

 

10,820

10,950

11,080

 

88 (31.1)

SHC

12,100

12,100

12,360

21,270

 

12,870

13,000

13,130

 

 

TC : Total Cooling Capacity (BTU/h)

SHC :

Sensible Heat Capacity (BTU/h)

NOTE

1. Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.

2. Above data represents the value when the operation frequency of a compressor is fixed.

33