2-2. Major Component Specifications

2-2-1. Indoor Unit

Indoor Unit CS-KS18NKU

Control PCB

Part No.

Controls

Control Circuit Fuse

Fan

CB-CS-KS18NKU

Microprocessor

250V 3A

 

Type

 

 

Cross-Flow

 

Q'ty ... Dia. and Length

inch (mm)

1 ... D3-5/8 / L33-9/32 (D92/L845)

 

 

 

 

 

 

Fan Motor

 

 

 

 

 

 

 

 

 

 

Type

 

 

DC Motor

 

Model ... Q'ty

 

 

SIC-41CVJ-D847-3 ... 1

 

No. of Poles

 

 

8

 

Rough Measure RPM (Cool)

 

 

1,250

 

Nominal Output

 

W

30

 

Coil Resistance

 

Ohm

-

 

(Ambient Temp. 68 °F (20 °C))

 

 

 

 

Safety Device

 

 

 

 

 

Type

 

 

Internal Controller

 

 

Over-Current Protection

 

 

Yes

 

 

Over-Heat Protection

 

 

Yes

 

Run Capacitor

 

Micro F

-

 

 

 

 

VAC

-

 

 

 

 

 

 

Flap Motor

 

 

 

 

Type

 

 

Stepping Motor

 

Model

 

 

MP24Z3

 

Rating

 

 

DC 12V

 

Coil Resistance

 

Ohm

Each Pair of Terminal : 400 +/- 7%

 

(Ambient Temp. 77 °F (25 °C))

 

 

 

 

 

 

 

 

Heat Exchanger Coil

 

 

 

 

 

 

 

 

 

 

Coil

 

 

Aluminum Plate Fin / Copper Tube

 

Rows

 

 

2

 

Fins per inch

 

 

19.5

 

Face Area

 

ft2 (m2)

3.07 (0.285)

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

15

Page 15
Image 15
Panasonic CU-KS18NKU service manual Major Component Specifications, Indoor Unit CS-KS18NKU