5.3 BIT ERROR RATE (V.52) DIAGNOSTICS

5.3 BIT ERROR RATE (V.52) DIAGNOSTICS

The NetLink-T1™ offers three V.52 Bit Error Rate (BER) test pat- terns. These test patterns may be invoked along with the LAL and RDL tests to evaluate the unit(s) and the communication links.

When a 511, 2047, or QRSS test is invoked, the NetLink-T1™ generates a pseudo-random bit pattern of 511 bits, 2047 bits or 220 bits, respectively, using a mathematical polynomial. The receiving NetLink- T1™ then decodes the received bits using the same polynomial. If the received bits match the agreed upon pseudo-random pattern, then the NetLink-T1™(s) and the communication link(s) are functioning properly.

511

Initiates a built-in 511 bit pseudo-random

 

pattern generator and detector.

2047

Initiates a built-in 2047 bit pseudo-random

 

pattern generator and detector.

QRSS

Initiates a built-in 220 bit pseudo-random

 

pattern generator and detector.

To perform a V.52 test, follow these steps:

1.Activate the local loopback or remote loopback diagnostic.

2.Activate the test pattern. This may be done in one of two ways:

a. Enter c Test Pattern from the System Diagnostics/Statistics menu and toggle the <Spacebar> until the desired test pattern appears.

b.One of two result codes will appear to the right of the c Test Pattern listing:

OK Indicates that the received test pattern is error-free.

BE Indicates that there are errors in the test pattern (to deliberately insert errors in the pattern, toggle

dError Insertion to ON).

APPENDIX A

PATTON NETLINK-T1 MODEL 2710

SPECIFICATIONS

WAN Speed:

1.544 Mbps

WAN Connection:

RJ-48C

Nominal Impedance:

100 Ohms

DTE Interface:

Integral V.35, M/34 mal

Line Coding:

AMI/B8ZS

Line Framing

D4/ESF/Unframed

Receive LBO:

Automatic

Transmit LBO:

Selectable - 0, 7.5,

 

15, or 22.5 dB, plus DSX-1

Clock Options:

Internal, external or network clock

Diagnostics:

Responds to CO-initiated D4 loopup

 

and loopdown codes, ESF line loop

 

and payload loop FDL messages,

 

Universal

 

Loopback De-activate message

Standards:

AT&T TR62411, TR54016, ANSI T1.403

Power Supply:

120VAC, 60 Hz to 5VDC 300mA wall-

 

mount transformer or UI 100-240VAC,

 

50 Hz to 5 VDC, 3A wall-mount trans-

 

former

Dimensions:

3.5”L x 2.1”W x 0.78”H (9.0 x 5.3 x 1.9

 

cm)