SmartNode 4630 Getting Started Guide1 • General information

 

Table 2. Rear panel ports (Continued)

 

 

Port

Description

 

 

BRI 0/1

ISDN BRI NT/TE port, RJ-45 socket S0 (S/T) interface (see figure 2), connects the

 

SmartNode with an ISDN device over an S/T bus, e.g. a PBX or an NT. The inter-

 

face may be used as fallback if connected to an NT. The port can be switched

 

between TE and NT mode.The interface is internally terminated with 100 Ohm.

 

Point-to-point or point-to-multipoint configurable. If the port is in NT mode a phantom

 

power supply can be switched on to supply connected phones with power.

 

 

BRI 0/2

ISDN BRI NT/TE port, RJ-45 socket S0 (S/T) interface (see figure 2), connects the

 

SmartNode with an ISDN device over an S/T bus, e.g. a PBX or an NT. The port

 

can be switched between TE and NT mode.The interface is internally terminated

 

with 100 Ohm. Point-to-point or point-to-multipoint configurable. If the port is in NT

 

mode a phantom power supply can be switched on to supply connected phones

 

with power.

 

 

BRI 0/3

ISDN BRI NT/TE port, RJ-45 socket S0 (S/T) interface (see figure 2), connects the

(SN4638 only)

SmartNode with an ISDN device over an S/T bus, e.g. a PBX or an NT. The port

 

can be switched between TE and NT mode.The interface is internally terminated

 

with 100 Ohm. Point-to-point or point-to-multipoint configurable. If the port is in NT

 

mode a phantom power supply can be switched on to supply connected phones

 

with power.

 

 

BRI 0/4

ISDN BRI NT/TE port, RJ-45 socket S0 (S/T) interface (see figure 2), connects the

(SN4638 only)

SmartNode with an ISDN device over an S/T bus, e.g. a PBX or an NT. The port

 

can be switched between TE and NT mode.The interface is internally terminated

 

with 100 Ohm. Point-to-point or point-to-multipoint configurable. If the port is in NT

 

mode a phantom power supply can be switched on to supply connected phones

 

with power.

 

 

Console

Used for service and maintenance, the Console port (see figure 2), an RS-232 RJ-45

 

connector, connects the product to a serial terminal such as a PC or ASCII terminal

 

(also called a dumb terminal). (9600 bps, 8 bits, no parity, 1 stop bit, no flow con-

 

trol).

 

 

100-240 VAC 50-

Electricity supply socket for mains power cable. (see figure 2).

60 Hz

 

 

 

Reset

The reset button (see figure 2) has three functions:

 

Restart the unit with the current startup configuration—Press (for less than 1 second)

 

and release the Reset button to restart the unit with the current startup configuration.

 

Restart the unit with factory default configuration—Press the Reset button for

 

5 seconds until the Power LED (see figure 3 on page 17) starts blinking to restart

 

the unit with factory default configuration.

 

Restart the unit in bootloader mode (to be used only by trained SmartNode tech-

 

nicians)—Starting with the unit powered off, press and hold the Reset button as

 

you apply power to the unit. Release the Reset button when the Power LED starts

 

blinking so the unit will enter bootloader mode.

 

 

SmartNode 4630 overview

16

Page 16
Image 16
Patton electronic 4630 Series manual BRI 0/1, BRI 0/2, BRI 0/3, BRI 0/4, Console, 100-240 VAC, Hz Reset