SmartNode 4630 Getting Started Guide

B • Specifications

 

 

Operating humidity: up to 90%, non condensing

Identification of the SmartNode devices via SNMP

All SmartNode devices have assigned sysObjectID (.iso.org.dod.internet.mgmt.mib-2.system.sysObjectID) numbers (see table 6).

Table 6. SmartNode Models and their Unique sysObjectID

SmartNode Model

SysObjectID

 

 

SN4634

.iso.org.dod.internet.private.enterprises.patton.products.sn46xx.1

 

1.3.6.1.4.1.1768.2.4.9.1

 

 

SN4638

.iso.org.dod.internet.private.enterprises.patton.products.sn46xx.2

 

1.3.6.1.4.1.1768.2.4.9.2

 

 

According to table 6, an SNMP get request to .iso.org.dod.internet.mgmt.mib-2.system.sysObjectIDof a Smart- Node 4634 device reads out a numeric OID of 1.3.6.1.4.1.1768.2.4.9.1, which represents a SmartNode 4634 device. The mapping of the sysObjectID to each of the SmartNode model is realized with the Smart- Node product identification MIB.

The SNMP agent running in SmartWare is SNMP version 1 (SNMPv1) compliant. SNMP version 2 (SNMPv2) and SNMP version 3 (SNMPv3) are not currently supported.

IMPORTANT

Identification of the SmartNode devices via SNMP

47

Page 47
Image 47
Patton electronic 4630 Series manual Identification of the SmartNode devices via Snmp, SmartNode Model SysObjectID