Patton electronic Model 3088/I manual DSL Error Monitor Configuration

Models: Model 3088/I

1 61
Download 61 pages 2.08 Kb
Page 24
Image 24
DSL Error Monitor Configuration

3088/I Getting Started Guide

3 • G.SHDSL config and status

 

 

DSL Error Monitor Configuration

The DSL Error Monitor provides various statistics for the DSL line. The monitor parameters are configured here. The error counters are also cleared from this menu.

Figure 9. DSL Error Monitor Configuration

The following shows the relationship of the DSL Error Monitor parameters:

Startup Delay

Interval #1

Interval #2

Interval #Total

Intervals

 

 

 

 

 

 

 

 

 

Start Up Delay

Interval Time (sec)

Interval Time (sec)

Interval Time (sec)

Interval Time (sec)

The DSL error monitor inspects intervals to see if they have met the error threshold (Max Interval Errors). If the error monitor finds a certain number (Interval Count) of intervals that meet or exceed the error threshold, it will restart the DSL link. The error monitor will wait (Start Up Delay) seconds after the DSL link comes up before it begins monitoring errors. After the startup delay, it will check the number of errors that have occurred during each (Interval Time) seconds to see if they meet the error threshold. The error monitor inspects (Total Intervals) intervals before it stops.

Note Setting Max Interval Errors to 0 disables the error monitor and setting

Total Intervals to 0 causes the error monitor to run continuously.

The following commands configure the error monitor:

Error Monitor Max Interval Errors: Sets the number of errors allowed in an interval causes it to be consid- ered an errored interval. If this is set to 0, then the error monitor is disabled.

Error Monitor Interval Time (sec): Sets the length of each interval.

Error Monitor Interval Count: Sets the number of errored intervals that causes the DSL link to restart.

Error Monitor Total Intervals: Sets the number of intervals to inspect for errors before disabling the error monitor. If this is set to 0, then the error monitor will run continuously.

Error Monitor Start Up Delay: Sets the number of seconds to wait after the DSL link comes up before the error monitor starts inspecting intervals.

DSL Error Monitor Configuration

24

Page 24
Image 24
Patton electronic Model 3088/I manual DSL Error Monitor Configuration