Problem

Action

 

 

Printing stops and

Calibrate the supply.

indicator light turns

1. Turn off the printer.

RED.

2. Load supply for non-peel mode.

Or,

See Chapter 3, “Loading

Printing is not lined

Supplies,” for more information.

up correctly on

3. Press and hold the FEED

supply.

button while turning on the

 

printer.

 

4. Release the FEED button after

 

the indicator light starts

 

flashing ORANGE. The printer

 

calibrates the black mark or die

 

cut sensor, measures the label

 

length, prints the test labels,

 

and calibrates the ribbon

 

sensor.

 

5. To resume normal printing, turn

 

off the printer, wait two

 

seconds, then turn it back on.

 

Problem with the supply. Load

 

different supply. See Chapter 3,

 

“Loading Supplies” for more

 

information.

 

Make sure the ribbon is not empty.

 

 

 

Make sure the black mark/die cut

 

sensor is set correctly for your

 

supply type. See “Adjusting the

 

Black Mark/Die Sensor,” for more

 

information.

 

Clear a label jam. See “Clearing

 

Supply Jams,” in Chapter 5 for more

 

information.

6-2Troubleshooting