4. Clean the platen roller when you see significant adhesive
adry,
If the brush does not remove
all the adhesive, use isopropyl alcohol on the platen roller. Moisten a cotton
swab with isopropyl alcohol and run the cotton swab across the platen roller. Turn the platen roller with your finger to make sure the platen roller is clean all the way around. After cleaning, feed several inches of supply through
without printing to remove any remaining isopropyl alcohol.
Platen Roller
5. Rub the cotton swab moistened with isopropyl alcohol across the peel bar and remove any
6. Moisten another cotton swab with isopropyl alcohol. Rub the cotton swab across the printhead and remove any
Printhead
Supply
Sensor
7. Rub the cotton swab across the supply sensor and die cut sensor and remove any
8. Clean the
9. Let the printer dry before you reload supplies.