Paxar 9855 RFID manual Flow control mismatch, Reference point off supply

Models: 9855 RFID

1 24
Download 24 pages 50.86 Kb
Page 18
Image 18

412Flow control mismatch.

413Online receive buffer is full. Check for a flow control problem.

611Font, bar code, or density in the batch does not fit the format.

612The data in this line of the batch is either missing or does not match the format.

613Reference point off supply.

614Portion of field off supply or there may be an invalid character in the packet.

703The printer sensed a calibration of different-sized black marks. Make sure the correct supply type is loaded.

704Printer has not sensed a supply mark when expected or is out of supplies. Press Escape/Clear and try to continue printing. Change supply.

715Invalid data length/data mismatch. The data in the RFID Data Field has an incorrect data length or there is a data type mismatch between selected data type and actual data entered. For more information about the data length and data type, refer to the RFIDMP Application Notes or the HF Application Notes. This error also occurs when there is an error in the Expanded C1Gen2 fields. Check with your System Administrator about your format.

740Command, hardware, inventory, or memory allocation error. There may be an RFID hardware or memory allocation error.

741RFID tag missing. Tag not found in RF Field. The RFID tag was not found in the RF Field (area inside the printer where RFID tag is programmed.) Check supply loading. If you made supply or print position settings, make sure the RFID tag was not moved out of the programmable range.

742Tag erase failed. The RFID tag was found in the RF Field, but could not be erased. Increase the number of retries. For more information, refer to the RFIDMP Application Notes or the HF Application Notes.

743Program tag failed. The RFID tag was found in the RF Field, but could not be programmed. Increase the number of retries. For more information, refer to the RFIDMP Application Notes or the HF Application Notes.

744Tag locked fail. The RFID tag is unable to be programmed because it is already locked. This is considered a bad RFID tag. For more information, refer to the RFIDMP Application Notes or the HF Application Notes.

16

Page 18
Image 18
Paxar 9855 RFID manual Flow control mismatch, Online receive buffer is full. Check for a flow control problem