Problem

Action

 

 

Blank labels print or 750

Clean supply sensors.

series errors.

 

Printer does not read or

See your System Administrator. Make sure the

program the RFID tag.

following are set correctly for your inlay (RFID tag)

 

type: Protocol (C1Gen1, EM4122), Read Power,

 

and Write Power. Refer to your RFID Setup Guide

 

& Supply Chart or HF Setup Guide & Supply Chart

 

for more information.

C o m m o n E r r o r s

If the action does not resolve the problem, call Service at the number listed on the inside front cover of this manual.

Error Description/Action

002Name must be 1 to 8 characters inside quotes.

005Supply width is invalid.

018Code page selection defined in the field is invalid.

025Data length is too long.

052Data type in the RFID Data Field must be 0, 1, 2, or 3. See your System Administrator for more information.

053The starting block in the RFID Data Field is invalid.

101Format referenced by batch not in memory.

226Rule Record Line xx. Upload device must be H (Host) for Option 6.

228Memory class identifier is invalid. The identifier must be A (AFI),

D (DSFID), or E (EAS) for Option 64. For more information, refer to the HF Application Notes.

229Byte code is invalid. Byte code must be an 8-bit (1 byte) character for Option 64. For more information, refer to the HF Application Notes.

230Lock code is invalid. Lock code must be 0 (Unlock) or 1 (Lock) for Option 64. For more information, refer to the HF Application Notes.

400Invalid character following {.

403Field separator was not found.

409Printer memory is full. Delete unnecessary formats or graphics from memory.

410Parity mismatch.

411Framing error (baud rate mismatch).