FICHA DE MEDIDAS DE CABLES

 

Medida

Poder

Poder

Poder

Longitud

de cables

Perdido

Perdido

Perdido

De cable

Aislados

a

a

a

(pies)

(AWG)

8 ohmios

4 ohmios

2 ohmios

______________________________________________________

5'

18 AWG

.79%

1.58%

3.16%

 

16

.5

1.0

2.0

 

14

.31

.62

1.24

 

12

.20

.40

.80

 

10

.125

.25

.50

10'

18 AWG

1.58%

3.16%

6.32%

 

16

1.0

2.0

4.00

 

14

.62

1.25

2.50

 

12

.40

.80

1.6

 

10

.25

.50

1.0

40'

18 AWG

8.0%

12.6%

25.2%

 

16

4.0

8.0

16.0

 

14

2.5

5.0

10.0

 

12

1.60

3.2

6.4

 

10

1.0

2.0

4.0

 

8

.625

1.25

2.50

80'

16 AWG

8.0%

16.0%

32.0%

 

14

5.0

10.0

20.0

 

12

3.2

6.4

12.8

 

10

2.0

4.0

8.0

25

Page 25
Image 25
Peavey ICA 400V, ICA Series, ICA 600, ICA 800V, ICA 2400V, ICA 1200 manual Ficha DE Medidas DE Cables