CONNECT WIRING

DANGER: Do not connect the power module to a supply circuit unless all ExSite system components (enclosure, camera module, and power module) are installed.

Refer to the following information to connect the wires and cables as required.

WARNING: When installing this unit, provide access to the communication wires (TX+ and TX-) to allow connection to the system for future software upgrades. Connectors must be installed so that the integrity of the hazardous location is maintained.

These communication wires are required even if the system uses Coaxitron® control.

Maximum wire distance for RS-422 data wires is 4,000 ft (1,219 m).

NOTES:

Relay 3 is allocated specifically for an external washer (not supplied by Pelco).

All relays are specified for 32 VDC, 0.5 A.

Wiring/cable for UTP and fiber optic are not provided on the wire harness. The installer must provide UTP and fiber optic connections.

Configuration of Wire Harness

Wire Color

Function

 

 

White/Orange

TX+

 

 

White/Blue

TX-

 

 

Red

RX+

 

 

Green

RX-

 

 

Violet/White

Relay 3 NC (washer only)

 

 

White/Red

Relay 3 COM (washer only)

 

 

Green/Black

Relay 3 NO (washer only)

 

 

Gray/White

Relay 2 NC

 

 

Yellow

Relay 2 COM

 

 

Violet

Relay 2 NO

 

 

Brown

Relay 1 NC

 

 

Gray

Relay 1 COM

 

 

White/Yellow/Black

Relay 1 NO

 

 

White/Black/Green

Alarm COM

 

 

White/Red/Black

Alarm 7

 

 

White/Brown/Black

Alarm 6

 

 

Orange

Alarm 5

 

 

White/Orange/Black

Alarm 4

 

 

White/Blue/Black

Alarm 3

 

 

White/Brown

Alarm 2

 

 

White/Black

Alarm 1

 

 

Video Coaxial Cable Requirements

Cable Type*

Maximum Distance

 

 

RG59/U

750 ft (229 m)

 

 

RG6/U

1,000 ft (305 m)

 

 

RG11/U

1,500 ft (457 m)

 

 

*Cable requirements: 75-ohm impedance All-copper center conductor

All-copper braided shield with 95% braid coverage

Power Connections 24 VAC

Wire Color

Function

 

 

Red

AC Hi

 

 

Black

AC Low

 

 

Power Connections 100-240 VAC

Wire Color

Function

 

 

Black

AC Hi

 

 

White

AC Low

 

 

Green/Yellow

Earth Ground

 

 

Wiring Distances

The following are the recommended maximum distances for 24 VAC and

100-240 VAC applications and are calculated with a 10 percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.)

 

 

Wire Gauge

 

Power

 

 

 

 

18

16

14

12

 

(1.0 mm2)

(1.5 mm2)

(2.5 mm2)

(3.5 mm2)

24 VAC

27 ft

43 ft

69 ft

110 ft

(8 m)

(13 m)

(21 m)

(33 m)

 

 

 

 

 

 

100-240

75 ft

120 ft

190 ft

310 ft

VAC

(23 m)

(36 m)

(58 m)

(94 m)

 

 

 

 

 

NOTE: Power consumption is 120 VA per unit. Use a power source with a minimum of 150 VA.