Pelco C3662M installation manual DS Enterprise Distributed System Installation

Models: C3662M

1 61
Download 61 pages 51.89 Kb
Page 31
Image 31
DS Enterprise Distributed System Installation

DS Enterprise Distributed System Installation

Install all physical equipment in a rack or other permanent location:

1.Install the XMUX2 units as described in XMUX2 Installation on page 28.

2.Install the DMS as described in DMS Installation on page 26.

3.Install the VAUs as described in VAU Installation on page 26.

Name the DMS:

1.Start the DMS.

2.On the DMS Desktop, right-click My Computer and select Properties.

3.Select the Network Identification tab.

4.Click Properties.

5.Type a computer name and click OK.

6.Click OK in the System Properties window.

7.Restart the DMS when prompted.

Configure the DMS TCP/IP address:

1.On the DMS Desktop, right-click My Network Places and select Properties.

2.Right-click Local Area Connection and select Properties.

3.Select Internet Protocol (TCP/IP) and click Properties.

4.Select “Use the Following IP Address” and enter a static IP address and subnet mask. Click OK.

5.Click OK in the Local Area Connection Properties window.

Point the VAUs to the Digital Sentry database on the DMS. Complete the following steps on each VAU:

1.Start the VAU.

2.From the VAU Start menu, open Settings>Control Panel>Administrative Tools>Data Sources (ODBC).

3.Select the System DSN tab.

4.Click Add.

5.Select SQL Server® and click Finish.

6.Type Digital Sentry in the Name field.

7.Type the name of the DMS for the Server.

8.Accept the default authentication and click Next.

9.Select Digital Sentry from the “Change the Default Database To” drop-down list. Click Next.

10.Accept the language and other settings and click Finish.

11.Click Test Data Source. If you do not see a message that indicates the test completed successfully, perform these steps again. Otherwise, click OK to close the ODBC configuration windows.

Verify that the VAUs and XMUX2 units are properly connected by completing the following steps on each VAU:

NOTE: Do not perform these steps until the XMUX2 units are properly installed and connected to the VAU, as described in XMUX2 Installation on page 28.

1.Run XPress WinView from Start>Programs>Integral. The application automatically detects all the XPress boards in the VAU and any connected XMUX2 units. Video from the first detected board is then displayed in the video windows.

2.Switch among all connected XMUX2 units using buttons 1-4 at the top of the main window.

30

C3662M (6/08)

Page 31