3.If a XMUX2 unit is not detected for an XPress board, eight black windows are displayed for that board. Check the connection between the XMUX2 unit and the selected XPress board.

4.If an input on the XMUX2 unit does not detect a video signal, only the input number is displayed in its assigned window. Check the connection between the camera and the input.

5.Name each VAU and assign a TCP/IP address.

Configure the DS Enterprise distributed system using DSAdmin:

The DSAdmin application is used to configure your DS Enterprise distributed system. A full discussion of DSAdmin can be found in the Digital Sentry System Software Operation/Configuration manual (C3661M) or the DS NVR and DS NVs System Software Operation/Confugration manual (C3663M). However, the basic steps used to configure the hardware components of your system are as follows:

1.Run DSAdmin on the DMS or any client computer from Start>Programs>Integral.

2.If a message appears indicating the Servers List file cannot be found, click No to create a new file. Click Save to accept the default file name and location.

3.Expand the folder in the directory tree to reveal Available Systems. Right-click Available Systems and select Add System to display the Add System window.

4.In the Add System window, enter the DMS name in the System Name field. Also enter the IP address of the DMS in the TCP/IP Address field. Then select AutoConnect and click Save.

5.Expand Available Systems in the directory tree to reveal the newly entered System Name. Right-click the system and select Refresh.

6.Expand the system and right-click the VAUs folder. Add the name and IP address of the first VAU and click Save. Right-click the VAUs folder again to add each remaining VAU.

7.To configure the XMUX2 units connected to a VAU, select the VAU in the directory tree and then the VAU Info tab. Select XMUX2, and then select Active for each XMUX2 unit. Select either NTSC or PAL as the video standard.

This completes the installation of the DMS, VAUs, and XMUX2 units. Refer to the Digital Sentry System Software Operation/Configuration manual (C3661M) for further DSAdmin instructions, including configuring camera recording, serial inputs, and setting up external storage.

Run the services:

1.From the VAU Start menu, open Settings and Control Panel.

2.Open Administrative Tools.

3.Open Services.

4.Right-click Digital Sentry Storage Service and select Start.

5.Right-click Digital Sentry VideoServer Service and select Start.

6.Right-click Digital Sentry WatchDog Service and select Start.

7.Right-click the VideoServer Service and select Properties. Change the Startup Type to Automatic. Repeat for the WatchDog Service and Storage Service.

8.Set up a master source time server on the network, as described in Using the FLTime Utility on page 43, and then start the service. The DMS must be the master server in a DS Enterprise distributed system.

C3662M (6/08)

31

Page 32
Image 32
Pelco installation manual C3662M 6/08

C3662M specifications

The Pelco C3662M is a state-of-the-art camera designed for robust surveillance and exceptional performance in various environments. Built for security applications, this camera features advanced imaging technology that ensures reliable monitoring and high-quality video capture.

One of the main features of the C3662M is its high-resolution image sensor. This sensor captures clear and crisp images, even in low-light conditions. With a resolution of 2 megapixels, the camera delivers detailed footage that can be crucial for identification purposes. The camera is capable of generating high-definition video streams, providing security operators with the clarity they need to assess any situation effectively.

The C3662M also incorporates advanced technology such as Wide Dynamic Range (WDR), which allows it to perform exceptionally well in scenes with contrasting lighting. This feature ensures that both the bright and dark areas of a scene are captured with excellent detail, making the camera particularly useful in environments like parking lots or entryways where lighting conditions can vary greatly.

Another critical characteristic of the C3662M is its low-light performance. Equipped with infrared (IR) capabilities, the camera can operate effectively in complete darkness, making it an ideal choice for 24/7 surveillance. The IR illumination allows the camera to capture clear images even when there is no visible light.

The C3662M is also designed for versatility in its deployment. It supports various mounting options and configurations, enabling users to install the camera in various locations, from indoor environments to outdoor settings. The rugged construction of the camera ensures it can withstand adverse weather conditions, making it suitable for use in challenging environments.

In terms of connectivity, the C3662M is compatible with various video management system solutions. It can easily integrate into existing security infrastructures, allowing for seamless operation and monitoring.

With its combination of high-resolution imaging, advanced WDR technology, and versatile installation options, the Pelco C3662M stands out as a premium choice for security applications. This camera addresses the needs of modern surveillance with reliability, ensuring that users can maintain peace of mind through effective monitoring capabilities.