Pelco c649m operation manual Rear Terminal Menu

Models: c649m

1 56
Download 56 pages 34.38 Kb
Page 24
Image 24

<REAR TERMINAL>

CALL OUT

WRNG•TAPE END

CLOCK OUT

REC- 1

MODE OUT

REC

REC IN

SERIES

Figure 13. Rear Terminal Menu

REC MODE

Sets the recording mode.

 

NORMAL<SP> – Choose SP (standard play) when higher

 

 

picture quality is desired. With this setting, the recording

 

 

time mode is switched in the following order: 2H, L24H,

 

 

48H, 72H, 96H, 120H, 168H, 0H, 2H.

 

H•D<EP> – Select the EP (extended play) setting to make

 

 

high density recording. This provides three times more

 

 

fields than normal density (SP). It reduces the time interval

 

 

between pictures, providing more pictures for smoother

 

 

time-lapse recording. With this setting, the recording time

 

 

mode is switched in the following order: 6H, L18H, 48H,

 

 

72H, 96H, 120H, 168H, 0H, 6H.

ONESHOT•

Sets the number of fields to record in the one-shot mode. When

FIELD

you turn the JOG dial to the right, the display switches in the

 

following order: 1, 2, 3, 4, 5, 10, 20, 30, 1. The default is 1.

ONESHOT•

Sets the interval time in one-shot mode. When you turn the

INTERVAL

JOG dial to the right, the display switches in the following order:

 

SHOT, 10S (second), 15S, 30S, 45S, 1M, 2M, 3M, SHOT. The

 

default is SHOT.

6.8 REAR TERMINAL MENU

CALL OUT

Sets the call signal output at the end of the tape. Turns on or off

 

the signal that comes from the CALL terminal when the end of

 

the tape is reached during recording. If any problems occur

 

during recording, a call signal is output from the CALL terminal

 

on the rear panel regardless of the CALL OUT setting. The

 

default is WRNG•TAPE END.

 

• WRNG•TAPE END – A signal is output at the end of the

 

tape or when a malfunction occurs.

 

• WRNG•REMAIN – The signal is output when a malfunc-

 

tion occurs in the VCR or when the tape has about three

 

minutes left in 2H mode.

 

• WRNG – When a malfunction occurs in the VCR during

 

recording, a call signal is output.

 

CALL OUT is used in conjunction with TAPE END (First Time

 

Set Up menu) to determine when the call signal is output, as

 

shown in Table B.

Table B. Call Out/Tape End

 

 

CALL OUT

 

 

 

TAPE END

setting

WRNG•TAPE END

WRNG•REMAIN

WRNG

setting

 

 

 

 

 

 

STOP

 

Outputs a call signal at the

Outputs a call signal 3 minutes

When a malfunction occurs in

 

 

end of the tape.

before the end of the tape

the VCR during recording, a call

 

 

 

 

 

signal is output

 

REWIND

 

Outputs a call signal at the

(same as above)

(same as above)

 

 

end of the tape for 2 seconds.

 

 

 

 

 

 

REPEAT

 

(same as above)

(same as above)

(same as above)

 

When there are no

(same as above)

(same as above)

(same as above)

 

ALARM

alarm recordings

during recording.

 

 

 

•PROT

 

 

 

 

 

When there are alarm

Outputs a call signal at the

(same as above)

(same as above)

 

 

recordings during

end of the tape.

 

recording.

 

 

 

 

24

Pelco Manual C649M (7/99)

Page 24
Image 24
Pelco c649m operation manual Rear Terminal Menu