Pelco c649m Alarm Recording Connection, External Time Clock Adjustment, 1st VCR 2nd VCR

Models: c649m

1 56
Download 56 pages 34.38 Kb
Page 38
Image 38

8.3.1 Alarm Recording Connection

You can confirm an alarm from a distance by connecting the ALM (alarm) OUT terminal to an existing alarm system panel or other external device such as a buzzer.

Alarm set

 

External alarm lamp

switch

 

 

and buzzer

 

 

SET

RST

REC

GND ALM MODE

CLK CALL

 

 

 

IN

 

 

OUT

RESET

 

 

 

 

 

 

ÉMIC

IN

AUDIO

OUT

 

 

REMOTE

 

 

 

IN

OUT

 

 

 

 

 

 

 

 

 

VIDEO

 

 

 

 

 

Alarm reset switch

 

Figure 23. Alarm Recording Connection

8.3.2 External Time Clock Adjustment

If ALARM REC DURATION in the Recording Set Up menu is set to other than MAN1, the on-screen clock can be reset to the nearest hour by applying a signal to the RST (reset) IN terminal. For example, if the current time is 11:29:59, it will be reset to 11:00:00; and if the current time is 11:30:00, it will be reset to 12:00:00.

*1

If the MODE terminal of the first VCR is connected to the RST (reset) IN

 

terminal of the second VCR and if MODE OUT in the Rear Terminal menu

is set to CLOCK ADJ, the second VCR’s on-screen clock will automati- cally be adjusted to that of the first VCR.

 

 

 

 

 

 

 

*1

 

 

SET

RST

REC GND ALM MODE

CLK

CALL

SET

RST

REC GND ALM MODE

CLK

CALL

 

IN

 

OUT

 

 

IN

 

OUT

 

 

 

1st VCR

 

 

 

2nd VCR

Figure 24. Time Clock Adjustment Connection

38

Pelco Manual C649M (7/99)

Page 38
Image 38
Pelco c649m operation manual Alarm Recording Connection, External Time Clock Adjustment, 1st VCR 2nd VCR