Pelco DD53CBW-X manual

Models: DD53CBW-X

1 56
Download 56 pages 43.11 Kb
Page 44
Image 44
Manual background

Aux

SPECTRA III

LANGUAGEENGLISH

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS>

ACK ALERT*

RESET CAMERA

CYCLE CAMERA POWER

REBOOT SYSTEM

EXIT

DOME SETTINGS

<CAMERA>

<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>

<WINDOW BLANKING> <ALARMS>

<AUX>

<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD>

BACK

EXIT

AUX

AUX 1 MODE

TOGGLE

DWELL TIME (SECS)

1

AUX 2 MODE

TOGGLE

DWELL TIME (SECS)

1

BACK

 

EXIT

 

An auxiliary output is a programmable signal from the dome back box that can trigger another device to operate. An auxiliary output is programmable to trigger from an alarm or from a controller.

An AUX 1 command from the controller will activate the relay in the dome and operate the device that is connected to the relay. The output of AUX 1 can be connected to the alarm input of a system switch to activate automatic monitor switching and recording.

An AUX 2 command from the controller will place a ground at the output of AUX 2 to operate the device that is connected to it.

The following are the available AUX MODE settings:

TOGGLE (default)

Changes the state of the auxiliary output every time an AUX command

 

is received from the controller.

LATCHING

Must receive an AUX ON/AUX OFF command from the controller to turn

 

the auxiliary output on/off.

MOMENTARY

An AUX ON command from the controller turns the auxiliary output on

 

for the programmed DWELL TIME. The auxiliary output will auto-

 

matically turn off when the dwell time is finished.

*This setting only applies to Pressurized Spectra III SE dome systems with software version 1.25 or higher.