Pelco DD53CBW-X manual Alarms, Quick Programming Guide

Models: DD53CBW-X

1 56
Download 56 pages 43.11 Kb
Page 41
Image 41
Alarms

Alarms

SPECTRA III

LANGUAGEENGLISH

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS>

ACK ALERT*

RESET CAMERA

CYCLE CAMERA POWER

REBOOT SYSTEM

The Spectra III SE dome has seven alarm inputs, which can be programmed as high, medium or low priority. When an alarm is received, an input signal to the dome triggers the user-defined action (go to preset, run pattern, etc.) programmed for the alarm.

There are three global alarm settings:

RESUME

This mode lets the dome resume its previous activity (scan, pattern, or

 

previous position) after all alarms are cleared.

EXIT

SEQUENCE

This is the time the dome will perform an alarm activity when more than

 

one alarm of the same priority occurs at the same time.

RESET DELAY

This is the amount of time the dome considers the alarm to be active after

 

it has physically cleared.

DOME SETTINGS

<CAMERA>

<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>

<WINDOW BLANKING> <ALARMS>

<AUX>

<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD>

BACK

EXIT

ALARMS

RESUME

OFF

SEQUENCE (SECS)

5

RESET DELAY (SECS)

0

<ALARM SETTINGS>

BACK

EXIT

ALARM SETTINGS

 

 

 

ALARM NUMBER

1

ALARM PRIORITY

LOW

ALARM ACTION

NONE

ACTIVATE AUX

NO

ALARM CONTACT

N/O

BACK

 

EXIT

 

Use the following steps to program alarm settings.

1.Use the joystick to position the cursor beside ALARM SETTINGS. Press Iris Open.

2.Select the alarm number:

a.Use the joystick to position the cursor beside ALARM NUMBER.

b.Press Iris Open. The cursor moves to the right.

c.Move the joystick up or down to view selections. Press Iris Open to enter selection.

(Continued on next page)

Quick Programming Guide

*This setting only applies to Pressurized

 

Spectra III SE dome systems with

 

software version 1.25 or higher.

(See page 11)

 

C2445M-E (11/05)

41

Page 41
Image 41
Pelco DD53CBW-X manual Alarms, Quick Programming Guide