Alarms
SPECTRA III
LANGUAGEENGLISH
<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
The Spectra III SE dome has seven alarm inputs, which can be programmed as high, medium or low priority. When an alarm is received, an input signal to the dome triggers the
There are three global alarm settings:
RESUME | This mode lets the dome resume its previous activity (scan, pattern, or |
| previous position) after all alarms are cleared. |
EXIT
SEQUENCE | This is the time the dome will perform an alarm activity when more than |
| one alarm of the same priority occurs at the same time. |
RESET DELAY | This is the amount of time the dome considers the alarm to be active after |
| it has physically cleared. |
DOME SETTINGS
<CAMERA>
<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>
<WINDOW BLANKING> <ALARMS>
<AUX>
<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD>
BACK
EXIT
ALARMS
RESUME | OFF |
SEQUENCE (SECS) | 5 |
RESET DELAY (SECS) | 0 |
<ALARM SETTINGS>
BACK
EXIT
ALARM SETTINGS |
|
|
|
ALARM NUMBER | 1 |
ALARM PRIORITY | LOW |
ALARM ACTION | NONE |
ACTIVATE AUX | NO |
ALARM CONTACT | N/O |
BACK |
|
EXIT |
|
Use the following steps to program alarm settings.
1.Use the joystick to position the cursor beside ALARM SETTINGS. Press Iris Open.
2.Select the alarm number:
a.Use the joystick to position the cursor beside ALARM NUMBER.
b.Press Iris Open. The cursor moves to the right.
c.Move the joystick up or down to view selections. Press Iris Open to enter selection.
(Continued on next page)
Quick Programming Guide
*This setting only applies to Pressurized |
|
Spectra III SE dome systems with |
|
software version 1.25 or higher. | (See page 11) |
|