Pelco DD53CBW-X Ack Action, Activate Aux, Current Reading, Reset Alert, Quick Programming Guide

Models: DD53CBW-X

1 56
Download 56 pages 43.11 Kb
Page 47
Image 47
ACK ACTION

SPECTRA III

LANGUAGEENGLISH

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS>

ACK ALERT

RESET CAMERA

CYCLE CAMERA POWER

REBOOT SYSTEM

EXIT

ACK ACTION

Acknowledge action programs the alert label behavior after the alert condition has been acknowledged. The following settings are available for ACK ACTION:

ALWAYS ON

The alert label is displayed until alert conditions are cleared.

OFF 8 HRS

The alert label is turned off for 8 hours. Label returns after 8 hours if the

 

alert condition persists.

OFF 24 HRS

The alert label is turned off for 24 hours. Label returns after 24 hours if the

 

alert condition persists.

OFF 48 HRS

The alert label is turned off for 48 hours. Label returns after 48 hours if the

 

alert condition persists.

DOME SETTINGS

<CAMERA>

<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>

<WINDOW BLANKING> <ALARMS>

<AUX>

<TITLE TEXT> <ALERT>

<CLEAR>

<PASSWORD>

BACK

EXIT

ALERT

 

REPEAT

CONSTANT

ACK ACTION

ALWAYS ON

ACTIVATE AUX

NO

<CURRENT READING>

 

RESET ALERT

 

BACK

 

EXIT

 

ACTIVATE AUX

This setting activates an auxiliary when an alert condition exists. ACTIVATE AUX settings include

the following:

 

NO (default)

Not activated.

1

An alert condition will close AUX 1.

2

An alert condition will close AUX 2.

CURRENT READING

The Current Reading menu displays the existing status of temperature, pressure, and dew point inside the dome system. An arrow displayed to the left of a menu item denotes that an alert condition exists.

An up arrow indicates the reading is over the threshold. A down arrow indicates the reading is below the threshold.

The high temperature alert occurs if the temperature is above 140°F (60°C). The low temperature alert occurs if the temperature is below -40°F (-40°C). The high pressure alert occurs if the pressure is above 11 PSIG.

The low pressure alert occurs if the pressure is below 1 PSIG.

The dew point (high humidity) alert occurs if the difference between the temperature and the dew point is less than or equal to 3°C.

NOTE: The normal operating temperature inside the unit will be greater than the temperature outside the back box due to the heat emitted by the system’s electronics.

CURRENT READING

TEMPERATURE

0°C

 

0°F

DEWPOINT

0°C

 

0°F

PRESSURE

0.0 PSIG

REFRESH

0.0 BAR

 

BACK

 

EXIT

 

RESET ALERT

Reset alert clears the alert condition and removes the alert label from the monitor. The system automatically checks internal conditions 60 seconds after reset. If conditions are still unaccept- able, the alert label reappears on the screen indicating further corrective action is required.

Quick Programming Guide

(See page 11)

C2445M-E (11/05)

47

Page 47
Image 47
Pelco DD53CBW-X manual Ack Action, Activate Aux, Current Reading, Reset Alert, Quick Programming Guide