SOFTWARE SETUP FOR A USB CONNECTED UPS DEVICE

SOFTWARE SETUP FOR A USB CONNECTED UPS DEVICE

To set up a USB connected UPS device:

1.Log in as an Administrator level user if you are not already.

2.Exit the DX8100 application and return to Windows operating system (refer to Exiting to Windows Operating System).

3.Click Start > Settings > Control Panel. The Control Panel opens.

Figure 95. Control Panel Window with Power Options Selected

4.Double-click Power Options. The Power Options Properties dialog box opens.

5.Click the Alarms tab.

6.Adjust the Critical Battery Alarm slider to the desired power level threshold.

The slider can be adjusted to signal an alarm when UPS battery power falls below the level you select. It is suggested that you set the value that provides at least five minutes of power in order to shut down the DX8100 safely. Refer to the documentation supplied with your UPS to determine the percentage value that will provide at least five minutes of reserve power.

7.Click Alarm Action under “Critical battery alarm.” The Power Options Properties dialog box opens.

￿

￿

￿

Figure 96. Power Options Properties Dialog Box