The DLCI number defined here is the Data Link Connection Identifier value provided by your frame relay service provider. This value must be set if auto-learning is disabled.

Each Remote Site PVC must be defined to exist on one of the two physical WAN links available on this router.

Primary Link

Location: Main

ªConfiguration

ªWAN Set up

ªRemote Site Set-up

ªEdit Remote Site

ªConnection Set-up

ªPrimary Link

The Primary Link value defines to which of the two physical WAN links that this PVC will be assigned. This value must be set.

Two other values must be set before the remote site profiles are fully configured, the CIR and EIR. The Committed Information Rate (CIR) option specifies the data rate that the Frame Relay service has guaranteed to provide. The Excess Information Rate (EIR) option specifies the data rate that the Frame Relay service indicates may be available for this PVC.

CIR

Location: Main

ªConfiguration

ªWAN Set up

ªRemote Site Set-up

ªEdit Remote Site

ªConnection Set-up

ªCIR

The CIR value specifies the guaranteed data rate for this PVC. This value must be set to the same as the value provided by the Frame Relay network provider. The value of 0 indicates that there is no commitment on the data rate.

Configuration: When changing the CIR option for this PVC, the PVC must be disabled and

Note

then enabled before the new value will take effect.