Applications

Identify the Connectors

P1705

The P1705 may be ordered with a 10Base2, 10Base5, or 10BaseT LAN interface.

If this P1705 has an ISDN U or S/T Module, it must only be installed in the slot 1 (leftmost position when viewed from the rear of the unit). The slot 2 position may be unused and covered with a blank panel or may contain another type of module. If a second WAN module is installed, only one BRI channel will be available for use.

Figure 1-2 Rear View of the P1705 with ISDN interface

P1730

The P1730 is configured with a 10/100BaseT LAN and either one or two optional interface modules. The optional modules may be a second LAN (10 BaseT), a second LAN plus one WAN module, a single WAN module or two WAN modules.

Important: If a second LAN module is installed, it must be in the slot 1 (leftmost position when viewed from the rear of the unit) to operate. In addition, if only one optional interface module is installed, it must be in slot 1

Each interface may be changed by simply removing the existing module and installing a new module. Refer to Appendix D: Servicing Information for information on replacing modules.

Link 1 module

Link 2 module LAN/Console module

 

 

MDI-X MDI

 

 

10/100 BT LAN

CSU/DSU

RS-232/V.24

CONSOLE

LINE

 

 

Power connector

Figure 1 -3 Rear View of the P1730 with a single LAN connection and two WAN

modules

3

Page 9
Image 9
Perle Systems 1700 manual Identify the Connectors, P1705, P1730