Maxos

Maxos electrical units

The electrical units for Maxos trunking sections can hold 1 or 2 TL5 or TL-D lamps and are designed for quick and reliable click-in mounting.They are made of steel with a white or silver coating.

The electrical units can be equipped with HFP electronic ballasts, HFR dimming ballasts (allowing light output of a TLD-lamp to be regulated from 3 to 100%), HF-DALI ballasts or low-loss conventional ballasts.

HFR and HF-DALI units must be mounted to 7-wire trunking sections. The conventional ballasts are available parallel compensated (IC) or inductive (I).

Special electrical units equipped with an emergency battery pack for 1 or 3 hours (EL1/EL3) are available.These units must be used with

7-wire trunking sections. If trunkings with double wiring are used, one flat ribbon cable will be connected to the central battery.This provides a completely separate emergency lighting circuit.

Some 2-lamp TL-D reflectors need dedicated electrical units (F32) with a short distance between the lamps. On request, the TL-D electrical units can be upgraded from IP20 to IP40 with an IP40 set that is available as an accessory.

 

 

Maxos TL5

 

 

 

Maxos TL-D

 

 

Electrical units

 

 

 

Electrical units

 

 

 

 

 

 

 

Type

 

4MX691

 

Type

 

4MX091

 

 

 

 

 

 

 

Lamp

 

Fluorescent:

 

Lamp

 

Fluorescent:

 

 

1 x or 2 x MASTER TL5 / G5 / 35, 54, 49, 80 W

 

 

 

1 x or 2 x MASTER TL-D / G13 / 36, 58 W

 

 

 

 

 

 

 

Gear

 

Electronic, 220 - 240 V / 50 - 60 Hz:

 

Gear

 

Electro magnetic (low loss), 230 or 240 V / 50 Hz:

 

 

High Frequency Performer (HFP)

 

 

 

Inductive, parallel compensated (IC)

 

 

High Frequency Regulator (HFR)

 

 

 

Electronic, 220 - 240 V / 50 - 60 Hz:

 

 

High Frequency Regulator, DALI (HFD)

 

 

 

High Frequency Performer (HFP)

 

 

 

 

 

 

High Frequency Regulator (HFR)

Option

 

Emergency lighting:

 

 

 

 

 

1 hour (EL1)

 

 

 

High Frequency Basic (HF-Dali)

 

 

3 hours (EL3)

 

 

 

 

 

 

 

Option

 

Emergency lighting:

 

 

 

 

 

 

 

Material

 

Sheet steel in white (WH) or silver (SI)

 

 

 

1 hour (EL1), 3 hours (EL3)

 

 

 

 

 

 

 

Installation

 

Click-in fixation (mechanical and electrical) on

 

 

 

2-lamp lampholder of 32 mm (F32) to be used in

 

 

trunking

 

 

 

facetted and aluminum reflectors, standard is 115

 

 

 

 

 

 

mm

 

 

 

 

 

 

 

 

 

 

 

 

Master/slave unit: pair of electrical units one with

 

 

 

 

 

 

gear (M) one without gear (S)

 

 

 

 

 

 

 

 

 

 

 

Material

 

Sheet steel in white (WH) or silver (SI)

 

 

 

 

 

 

 

 

 

 

 

Installation

 

Click-in fixation (mechanical and electrical) on

 

 

 

 

 

 

trunking

 

 

 

 

 

 

 

 

 

 

 

Remarks

 

Dedicated IP40 sets for upgrading from IP20 to

 

 

 

 

 

 

IP40

 

 

 

 

 

 

 

Where relevant, for detailed descriptions of Lighting Controls we refer you to chapter 11, and descriptions for e.g. optics/optical covers, lamps data, photometrical diagrams, etc. to the respective sections in chapter 12.

8.20

Light-line systems

Philips indoor luminaires

Page 21
Image 21
Philips TTX400 manual Maxos electrical units