Linesense

With Linesense,TTX400 and controls are combined in one.The speed and ease of installation of TTX400 remains when Linesense is used. In addition, substantial energy savings up to 75% can be achieved. Linesense has been developed for industrial applications like warehouses.

Installation clicks only

1 ZTX400 MDU control unit clicks onto the trunking.

2 Movement detector clicks on the bracket.

3 ZTX400 MB-MDU bracket clicks on the trunking.

4 Telejack cables click the detector and control unit together. 5 ZTX400 CU mains connection clicks on the control unit.

TTX400

Light-line systems

ZTX400 MDU

Pre-wired Linesense unit with integrated control function

ZTX400 MB-MDU

Mounting bracket for

movement detector

LRM8117/00

Daylight linking Manual override

Movement detection

 

 

 

 

 

 

 

Switch on/off

 

 

 

 

or dim to

 

Switch on/off

 

 

10, 20, 30%

 

 

 

 

 

 

 

LRM8117/00

High-bay passive infrared movement detector Mounting height up to 15 m

 

 

Best performance

Best economy

Linesense consists of a 618 mm piece

 

 

ZTX400 MDU HFD

ZTX400 MDU HFP

of trunking, which is fully pre-equipped

 

Movement detection (detector LRM8117)

 

 

and wired to be added to the trunking.

 

Minimum light level without presence

0, 10, 20, or 30%

0

The control function is integrated into

 

Maximum number of presence detectors per control unit

4

2*

this extra unit, and can easily be clicked

 

Maximum cable length for movement detector

300 m

125 m

between the light line and the electrical

 

 

 

 

connection unit. High bay movement

 

Daylight linking (light sensor LRL8102)

 

-

detectors are connected with standard

 

Number of light sensors per control unit

1

-

RJ-12 cables and mounted at the right

 

 

 

 

location with the use of dedicated

 

Manual control

 

-

brackets. Linesense is equipped as

 

(on, off and override)

 

 

standard with a telejack splitter to

 

 

 

 

easily connect the detectors to the

 

Type of ballast

HFD***

HFP

light line.

TTX

Maximum number of ballasts per line

64

**

 

400

TTX400 system

7 wire

5 wire

 

 

 

*2 presence detectors or 3 with LED disabled

**any number of luminaires allowed by the TTX400 light line system

***HFD=HFR-DALI

Philips indoor luminaires

Light-line systems

8.39

Page 40
Image 40
Philips TTX400 Pre-wired Linesense unit with integrated control function, Location with the use of dedicated, Light line