Philips indoor luminaires8.54 Light-line systems
TTX400
TTX400 trunking sections
This trunking system for TL5 and TL-D lamps comprises prewired
sections (TTX400) and optional unwired sections (TTX410). The
sections can be easily clicked together using the integrated electrical/
mechanical coupling pieces. The trunking is available with a complete
range of interchangeable components to offer outstanding exibility.
All the trunking sections are made of white prelaquered steel. Round
edges reduce the risk of injury. Flat-ribbon cable (5 or 7 wires), an
integrated phase-selection switch and contact blocks with click
connection make electrical and mains connection quick, simple and
safe (if 3 phases are used equalised, the maximum current is 16 A).
The rigidity of the sections and coupling pieces limits the number of
mounting brackets needed (max. 3 meters when using 493 trunking
sections). The electrical unit is simply clicked into the trunking for both
mechanical and electrical connection.
The prewired section TTX400 is equipped standard with a 5- or
7-wire 2.5 or 1.5 mm² at ribbon cable. The 7-wire at ribbon cable
is used especially for the integration of light regulation or emergency
lighting functions. Hence, no extra contact blocks or wiring need to be
installed. TTX400 is available in lengths of 1, 2 and 3 electrical units of
TL5 28/54 W, 35/49/80 W and TL-D 36 W and 58 W. It is also available
in 9 wires (7-wire at-ribbon plus 2 additional low-voltage cables for
dimming) for the integration of light regulation and emergency lighting
functions. The new optimized and recommended solution, instead of
TTX400 9, consists of the standard TTX400 7-wire at-ribbon and the
new electrical units TMX400 C-2R.
TTX400 is also available with a 5-wire 1.5 mm² ribbon cable, in the
same lengths as mentioned before; to be used in combination with
HFP units.
TTX400 TL5
Standard trunkings
Type TTX400 (prewired)
Length 1 x, 2 x or 3 x length of electrical unit 49 (491, 492
or 493), also applicable for 80 and 35 W electrical
unit
1 x, 2 x or 3 x length of electrical unit 54 (541, 542
or 543), also applicable for 28 W electrical unit
Electrical circuit option TTX400 5: 1 x at ribbon cable, 5 wires, 1.5 and
2.5 mm²
5-wire: standard at ribbon cable (5)
TTX400 7: 1 x at ribbon cable, 7 wires, 2.5 mm²
7-wire: standard at ribbon cable (7)
TTX400 9: 9-wires
7-wire standard at ribbon cable + 2 hardcore
cables 1 mm² (9)
7-wire standard at ribbon cable + 2 cables
1 mm² for communication purpose (9T)
Alternative to TTX/TMX400 9 : TTX400 7 +
TMX400 C-2R
Phase selection switch and contact blocks with
click connection are integrated
Connection Connection box ZTX400 CU or ZTX400 CM
Trunking piece TTX400 CU7 (to be completed
with ZTX400 EP-CU)
Universal TTX400 CM-CU for cable entry at the
beginning of light-line or in the middle
Material Steel, prelacquered white
Accessory Suspension/mounting brackets, external coupling
piece, etc, see TTX400 accessory section
Where relevant, for detailed descriptions of Lighting Controls we refer you to chapter 11, and descriptions for e.g. optics/optical covers, lamps data, photometrical diagrams, etc. to the respective sections in chapter 12.
TTX400 TL-D
Standard trunkings
Type TTX400 (prewired)
Length 1 x, 2 x or 3 x length of electrical unit 36 or 58 W
(361, 362 or 363 resp 581, 582 or 583)
Electrical circuit option TTX400 5: 1 x at ribbon cable, 5 wires, 1.5 and
2.5 mm²
5-wire: standard at ribbon cable (5)
TTX400 7: 1 x at ribbon cable, 7 wires, 2.5 mm²
7-wire: standard at ribbon cable (7)
TTX400 9: 9-wires
7-wire standard at ribbon cable + 2 hardcore
cables 1mm² (9)
7-wire standard at ribbon cable + 2 cables
1 mm² for communication purposes (9T)
Alternative to TTX/TMX400 9 : TTX400 7 +
TMX400 C-2R
Option:
1, 2, 3 section prewired trunking with 2 circuits
at ribbon 5 wires (2C5)
1, 2, 3 section prewired trunking with 2 circuits
at ribbon 7 wires (2C7)
Phase selection switch and contact blocks with
click connection are integrated
Connection Connection box ZTX400 CU or ZTX400 CM
Trunking piece TTX400 CU7 (to be completed
with ZTX400 EP-CU)
Universal TTX400 CM-CU for cable entry at the
beginning of light-line or in the middle
Material Steel, prelacquered white
Accessory Suspension/mounting brackets, external coupling
piece, etc, see TTX400 accessory section
Indoor_2008_Chapter_08_LIS.indb 54 20-05-2008 13:25:53