VENTILATION AND FIRE SAFETY SYSTEMS

VENTILATION AND FIRE SAFETY SYSTEMS

Your new fryer must have proper ventilation to function safely and properly. Exhaust gas temperatures can reach as high as 1000°F. Therefore, it is very important to install a fire safety system. Your ventilation system should be designed to allow for easy cleaning. Frequent cleaning of the ventilation system and the fryer will reduce the chances of fire. Table 1-2 provides a list of reference documents that provide guidance on ventilation and fire safety systems. This table is not necessarily complete. Additional information can be obtained from CSA International, 8501 East Pleasant Valley Road, Cleveland,OH44131.

Excessive ventilation causes drafts, which will interfere with the proper operation of the pilot and the burner. Leave at least 18 inches of open space between the fryer's flue vent opening and the intake of the exhaust hood.

CAUTION

Ensure that your ventilation system does not cause a down draft at the fryer's flue opening. Down drafts will not allow the fryer to exhaust properly and will cause overheating which may cause permanent damage. Damage caused by down drafts will not be covered under equipment warranty. NEVER allow anything to obstruct the flow of combustibles or ventilation exiting from the fryer flue. DO NOT put anything on top of the flue area.

NOTICE

NEVER connect the blower directly to the flue openings. The direct flow of air will cause poor temperature recovery, poor ignition, inefficient operation of the fryer, and could extinguish the pilot.

Table 1-2 Ventilation and Fire Safety References

 

TOPIC

UNDERWRITERSLABORATORY

NATIONALFUELGAS

 

DOCUMENT

CODEDOCUMENT

 

 

 

EXHAUST HOODS

ANSI/UL 710

ANSI/NFPA96

POWER VENTILATORS

ANSI/UL 705

ANSI/NFPA 96

FILTER UNIT

ANSI/UL 586

ANSI/NFPA 96

 

ANSI/UL 900

 

TYPES OF FIRE EXTINGUISHERS

 

AND DETECTION EQUIPMENT

 

CO2

ANSI/UL 154

ANSI/NFPA 12

DRYCHEMICAL

ANSI/UL 299

ANSI/NFPA17

WATER

ANSI/UL 626

ANSI/NFPA 13

FOAM

ANSI/UL 8

ANSI/NFPA 11

SPRINKLERS

ANSI/UL 199

ANSI/NFPA 13

SMOKE DETECTORS

ANSI/UL 268

ANSI/NFPA 72

FIRE DETECTION THERMOSTATS

ANSI/UL 521

ANSI/NFPA

Gas pressure check

Gas pressure should be measured at the burner manifold and should match the pressure requirement

ENGLISH

L20-206 Rev2(07/02)

3

 

Page 5
Image 5
Pitco Frialator SG English, Ventilation And Fire Safety Systems, 2 Ventilation and Fire Safety References, Topic, Document