5.6 Use External Housing (with CAM-OH)

To operate speed dome cameras and maintain all functions in normal in severe temperature conditions, i.e. below -10oC or above 45oC, external housing is required.

CAM-OH has included two brackets (Ceiling-mount and Wall-mount bracket). You can choose which one you will like to used.

Inside the housing, the mounting base (item # 3 in the accessory list) is already built before it leaves factor. (see

picture on the right).

Wall mount Installation Procedure

1.Take the wall mount bracket, put it on the target place and fix it with the supplied screws (total of 4).

2.Take the cover-screw off from the bracket, and remove the cover.

Remove this screw

3.Please stuff the water proof rub ring into the bracket. Then attach the bracket and lock it to the housing. Tight them on with screws.

.

.